Baumer GIM500R 매뉴얼 - 페이지 29

{카테고리_이름} Baumer GIM500R에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer GIM500R 29 페이지. Inclination sensors
Baumer GIM500R에 대해서도 마찬가지입니다: 매뉴얼 (20 페이지), 매뉴얼 (13 페이지), 조립 지침 (2 페이지)

Baumer GIM500R 매뉴얼
4

Terminal assignment

M12 flange connector, 5-pin

4.1
Pin
Assignment
1
CAN_GND
2
+Vs
3
GND
4
CAN_H
5
CAN_L

2xM12 flange connector, 5-pin

4.2
Pin
Assignment
1
CAN_GND
2
+Vs
3
GND
4
CAN_H
5
CAN_L
Terminals with the same designation are connected to each other internally and identical in their functions.
Maximum load on the internal clamps Vs-Vs and GND-GND is 1 A each.

Cable

4.3
Core color
Assignment
White
+Vs
Brown
GND
Green
n.c.
Yellow
n.c.
Grey
n.c.
Pink
CAN_H
Blue
CAN_L
Red
CAN_GND
Baumer_GIM500R_CANopen_MA_EN.docx
03.19
Description
Ground connection relating to CAN
Voltage supply
Ground connection relating to +Vs
CAN Bus signal (dominant High)
CAN Bus signal (dominant Low)
Description
Ground connection relating to CAN
Voltage supply
Ground connection relating to +Vs
CAN Bus signal (dominant High)
CAN Bus signal (dominant Low)
Description
Voltage supply
Ground connection relating to +Vs
-
-
-
CAN Bus signal (dominant High)
CAN Bus signal (dominant Low)
Ground connection relating to CAN
29/29
M12 (male)
M12 (male/female)
www.baumer.com