Baumer OM30 Manuale operativo - Pagina 10

Sfoglia online o scarica il pdf Manuale operativo per Strumenti di misura Baumer OM30. Baumer OM30 48. Laser distance sensors

Baumer OM30 Manuale operativo
3
|
Description
3.3

Measurement field

INFO
The data for your sensor version can be found in the data sheet.
ZP
ZP
Sdc
Sde
Blind region (CD)
Region in which the sensor cannot detect any measurement objects.
n
Unwanted objects (objects not to be measured) in this region may lead to deviations in the
n
measurement results.
Measuring range (MR)
Region in which the measurement object must be present for the sensor to deliver reliable
n
measurement results.
Unwanted objects (objects not to be measured) in this region may lead to deviations in the
n
measurement results.
The limits of the measurement range (MR) are defined via the parameters Start of the mea-
n
surement range (Sdc) and End of the measurement range (Sde).
Zero position (ZP)
Reference point for the distance measurement (relative measurement).
n
The zero position is located on the front of the sensor. The output consists of the distance
n
between the front of the sensor and the measurement object.
Factory setting: ZP = 0 mm
n
Basis for:
n
▪ Output measured values
▪ Analog value
▪ Switching points
Capable of parameterization via:
n
▪ IO-Link
▪ Teach button
10
CD
Sdc
MR
Sde
Zero position
Start of the measurement range
End of the measurement range
Operating Manual
CD
Blind region
MR
Measurement range
Baumer
OM20/OM30 | V1