Section 3
As with any electronic device, you should place the switch where it will not be subject to
Selecting a
extreme temperatures, humidity, or electromagnetic interference that exceeds the
Site
RJSMLAC-8MG-CAPS
requirements:
CAPS for
The switches are pre-equipped with caps on all ports, including power and Ethernet.
unused
connectors
and prevent from deterioration of the contacts.
The RJSMLAC-8MG-CAPS Ethernet Switch can be fastened to any flat surface by
Mounting
mounting the box directly. Refer to the mechanical drawings below. Make sure to allow
enough room to route your Ethernet and power cables.
The RJSMLAC-8MG-CAPS weights 1.8 Kg and is mounted via its four 4x4.5 mm holes for
screws.
The external dimensions of the RJSMLAC-8MG-CAPS are given here after.
RJSMLAC 8MG CAPS UM

Installation

The ambient temperature should be between -35 to 75 degrees Celsius.
The relative humidity is recommended to be less than 95% percent, non-
condensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards for MIL-STD-461E.
Make sure all connectors are protected with cap or sealed plug to ensure sealing
www.amphenol-socapex.com
's profile. Specifically, the site you select should meet the following
Rev: 4.0
Page 5 of 13