7.1 Jetsave and Dosave
7.1.1
Connection of the tube
The machine is prepared for connection to the dosing systems Jetsave and Dosave.
The connections are closed at delivery. Open any of the connections that shall be used by drilling a hole where the
tube shall be connected.
Note!
Make sure there is no burrs left after drilling. When removing burrs make sure burrs does not fall into the si-
phon breaker.
A = ⌀ 17 mm (used for dosing systems).
B = ⌀ 6 mm (used for dosing systems).
C = Only used for flush manifold. (Separate instructions enclosed when ordering).
Always connect hoses on connections (A) with a hose clamp.
For connections (B); if the hoses are made of a soft material such as silicone or similar, use a cable tie to fasten the
hose on the connection. If the hoses are made of a hard material, it is not recommended to make the connection
tighter by using a cable tie.
Note!
Equipment for external dosing must only be connected to work on pump pressure and not on network
pressure.