3.3 PROCEDURE FOR ENTER THE CORRECTION FACTOR DIRECTLY
Carefully follow the procedure indicated below.
FORMULA
Proper correction factor = current correction factor×(actual value/ display value)
Example:
Actual value
Display value
Current correction factor
Proper correction factor
1
Wait for the meter to go to standby.
2
Reset the resettable total.
3
Press the MENU key. Keep it pressed until similar
�ith the image sho�ed �the digit flash in
means the meter is in correction factor modification
mode.
4
Press the RESET key to choose the right digit from 0
to 9. Press the MENU key to start the next digit. So
the digit of correction factor can be changed one by
one.
5
Make sure the correction factor is right, press the
MENU key. Keep it pressed until quit calibration
mode, the factor is saved. The meter goes to standby
again.