3.3 PROCEDURE FOR ENTER THE CORRECTION FACTOR DIRECTLY
Carefully follow the procedure indicated below.
FORMULA
Proper correction factor = current correction factor×(actual value/ display value)
Example:
Actual value
Display value
Current correction factor
Proper correction factor
1
Wait for the meter to go to standby.
2
Reset the resettable total.
3
Press the MENU key. Keep it pressed until similar
�ith the image sho�ed �the digit flash in
means the meter is in correction factor modification
mode.
4
Press the RESET key to choose the right digit from 0
to 9. Press the MENU key to start the next digit. So
the digit of correction factor can be changed one by
one.
5
Make sure the correction factor is right, press the
MENU key. Keep it pressed until quit calibration
mode, the factor is saved. The meter goes to standby
again.
NSW
QLD/PNG
TEL: (02) 9939 0711
TEL: (07) 3204 9166
FAX: (02) 9939 0411
FAX: (07) 3204 1224
Visit our website at
Instructions for the 51037M
20.75
18.96
1.000
1.000×(20.75/18.96)=1.000×1.094=1.094
VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266
www.alemlube.com.au
�one�, it
WA
SA/NT
TEL: (08) 9302 4199
TEL: (08) 8241 7111
FAX: (08) 9303 2095
FAX: (08) 8241 7011
NZ
TEL: (09) 447 1007
FAX: (09) 447 1008
5