Formax FD 87HD Manuale di manutenzione - Pagina 7

Sfoglia online o scarica il pdf Manuale di manutenzione per Apparecchiature industriali Formax FD 87HD. Formax FD 87HD 14. Hard drive punch
Anche per Formax FD 87HD: Manuale dell'operatore (2 pagine)

Formax FD 87HD Manuale di manutenzione
Troubleshooting Motor Issues
If the motor doesn't work, check wiring connections to be sure they're attached properly. Check connections
between motor and the following: start condenser, motor start relay and running condenser.
Start condenser
Motor start relay
Running condenser
Reduction chain
Troubleshooting Feed Slot
If the feed slot does not adjust to fit both hard drive sizes (2.5" and 3.5"), one or both of the fixed springs may
be damaged or broken. Replace the broken spring(s).
Feed slot
Motor
Front spring
Rear spring
Troubleshooting Feed Chamber Trap Door
If the feed chamber trap door does not operate (releasing the punch hard drive into the waste bin), the trap
door springs may be damaged or broken. Replace the broken spring(s).
Rear springs
Front springs
5