Formax FD 87HD Bakım Kılavuzu - Sayfa 7

Endüstriyel Ekipmanlar Formax FD 87HD için çevrimiçi göz atın veya pdf Bakım Kılavuzu indirin. Formax FD 87HD 14 sayfaları. Hard drive punch
Ayrıca Formax FD 87HD için: Operatör El Kitabı (2 sayfalar)

Formax FD 87HD Bakım Kılavuzu
Troubleshooting Motor Issues
If the motor doesn't work, check wiring connections to be sure they're attached properly. Check connections
between motor and the following: start condenser, motor start relay and running condenser.
Start condenser
Motor start relay
Running condenser
Reduction chain
Troubleshooting Feed Slot
If the feed slot does not adjust to fit both hard drive sizes (2.5" and 3.5"), one or both of the fixed springs may
be damaged or broken. Replace the broken spring(s).
Feed slot
Motor
Front spring
Rear spring
Troubleshooting Feed Chamber Trap Door
If the feed chamber trap door does not operate (releasing the punch hard drive into the waste bin), the trap
door springs may be damaged or broken. Replace the broken spring(s).
Rear springs
Front springs
5