ANDERBERG KLIMA HP50 Manuale di istruzioni - Pagina 8

Sfoglia online o scarica il pdf Manuale di istruzioni per Deumidificatore ANDERBERG KLIMA HP50. ANDERBERG KLIMA HP50 12.

16. Specifications

Nominal airflow
(m³/H)
Supply voltage
Power consumption *
Range of application ºC
Range of application RH
Weight
Dimensions (WxHxD)
Defrosting
Refrigerant
Drying capacity
Operating hours counter
* at 26,7°C – 80% humidity
17. Troubleshooting
Trouble
Unit can´t be switched on
(LED „Standby" doesn´t light up)
Unit is turned on but doesn´t dehumidify (no
water in the tanks)
Model
n= 1700 rpm
n= 1400 rpm
27ºC – 80%
32ºC – 80%
No power to the unit
Main switch not in
position „ON"
Fuse is defective
The ambient
temperature is below
+1°C
The ambient
temperature exceeds
+35 °C
The humidity of the
ambient air is below 30
% r.h.
The air filters are dirty
Not enough operating
time yet
DHI Pro 50
1065
885
230V – 50Hz
950 W
+1/+35°C
30% - 90%
42 kg without tanks, 45 kg with tanks
54 x 78 x 48 cm
Hot gas bypass
R407C
45 ltrs/24h
50 ltrs/24h
Possible cause
Plug in the mains;
check power at the outlet
Switch on the unit
Contact your retailer
Under these conditions the operation of
the device is inefficient. We recommend
turning off the unit or raise the ambient
temperature where possible.
Under these conditions the compressor
of the dehumidifier is overloaded and
the device automatically shuts down.
We recommend turning off the
dehumidifier.
Under these conditions the operation of
the device is inefficient. We recommend
turning off the unit.
Clean / replace the air filters.
Keep the unit running and observe. It
may be some time after switching on,
before the water starts to collect in the
tanks.
Remedy