Sfoglia online o scarica il pdf Manuale per Apparecchiature industriali ATI Technologies RCV. ATI Technologies RCV 6. Vane motor rebuild
Manual, RCV Vane Motor Rebuild
Document #9610-50-1033-02
Troubleshooting
Trouble
Low Power
Low Power
Low Power
Motor will not run
16
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
Possible Cause
Solution
Worn and/or broken
Remove the Motor Assembly. Discard the Vanes and
Vanes
replace all Vanes with new ones.
Worn/damaged Cylinder
Remove Motor Assembly. Inspect the inner diameter
of the Cylinder. If there is any scoring or a wear
marks, replace with a new one.
Debris in Motor
Completely disassemble tool. Clean all parts with a
Assembly/Motor Housing
suitable solvent in a well ventilated work space.
Swollen Vanes
Remove the Motor Assembly. Discard the Vanes and
replace all Vanes with new ones.
6
www.ati-ia.com