THERMOSTAT
R
C
G
(REMOVE)
Y
W
Figure 5: Humidistat Wiring Diagram
Wiring Notes/ Cautions
Do not connect duct sensor backwards. Always verify the correct
placement of the duct sensor terminal to the main humidistat board.
Verify the wiring before powering on.
Verify that the humidistat output matches the humidifier input type
(Figure 6).
o
ON/OFF
o
Modulating (0-10V
Figure 6: Verify Control Signal Types Match
Form 16763
RESIDENTIAL HUMIDISTAT
R
C
FURNACE
R
C
G
Y
W
DC
CARNES HUMIDISTAT
+
W G
H1 H2 GF
ODT ODT
OUTDOOR
TEMP
SENSOR
)
|
Installation
-
CARNES
HUMIDIFIER
+
24
-
24
HUM
GND
11