THERMOSTAT
R
C
G
(REMOVE)
Y
W
Figure 5: Humidistat Wiring Diagram
Wiring Notes/ Cautions
•
Do not connect duct sensor backwards. Always verify the correct
placement of the duct sensor terminal to the main humidistat board.
•
Verify the wiring before powering on.
•
Verify that the humidistat output matches the humidifier input type
(Figure 6).
o
ON/OFF
o
Modulating (0-10V
Figure 6: Verify Control Signal Types Match
Form 16763
RESIDENTIAL HUMIDISTAT
R
C
FURNACE
R
C
G
Y
W
DC
CARNES HUMIDISTAT
+
W G
H1 H2 GF
ODT ODT
OUTDOOR
TEMP
SENSOR
)
|
Installation
-
CARNES
HUMIDIFIER
+
24
-
24
HUM
GND
11