Electrolux EFC 6940 Manuale d'uso - Pagina 7

Sfoglia online o scarica il pdf Manuale d'uso per Cappa di ventilazione Electrolux EFC 6940. Electrolux EFC 6940 13. Electrolux cooker hood
Anche per Electrolux EFC 6940: Manuale d'uso (16 pagine), Manuale d'uso (16 pagine), Manuale d'uso (16 pagine)

Electrolux EFC 6940 Manuale d'uso

Charcoal filter

• The charcoal filter should only be used if you
want to use the hood in its filtering function.
• To do this you will need an original
ELECTROLUX charcoal filter (see special
accessories).
• Cleaning/replacing the carbon filter
Unlike other carbon filters, the LONGLIFE
charcoal filter can be cleaned and reactivated.
At normal use the filter should be cleaned every
second month. The best way to clean the filter
is in the dishwasher. Use normal detergent and
choose the highest temperature (65º C). Wash
the filter separately so that no food parts gets
stuck on the filter and later causes bad odours.
To reactivate the charcoal, the filter should be
dried in an oven for 10 minutes with a tempera-
ture of maximum 100º C.
After approximately three years of use, the
carbon filter should be replaced with a new, as
the odour reduction capacity will be reduced.
• Mounting
Remove the frame i which supports the filter h
by turning 90° the two knobs g, Fig.5. Insert
the coal mattress inside the frame and put all
parts back in their place.
• To dismount proceed in reverse order.
• Always specify the hood model code number
and serial number when ordering replacement
filters. This information is shown on the
registration plate located on the inside of the
unit.
• The charcoal filter can be ordered from the
ELECTROLUX technical assistance service.

Changing the light bulb

• Disconnect the cooker hood from the main
supply.
• Remove the lamp cover, use a screw driver as a
lever. Fig. 6.
• Replace the old bulb with a new one of the
same type.
• Remount the lamp cover.
• If the light does not come on, make sure the
bulb has been inserted in correctly before
contacting the technical assistance service.
Fig. 5
Fig. 6
34