Electrolux EFC 6940 Manuale d'uso - Pagina 8

Sfoglia online o scarica il pdf Manuale d'uso per Cappa di ventilazione Electrolux EFC 6940. Electrolux EFC 6940 13. Electrolux cooker hood
Anche per Electrolux EFC 6940: Manuale d'uso (16 pagine), Manuale d'uso (16 pagine), Manuale d'uso (16 pagine)

Electrolux EFC 6940 Manuale d'uso

Technical Specifications

Dimensions
Height
Width
Depth
Lighting
Grease filter
power absorption
We reserve the right to generate constructive and chromatic modifications as required by technological growth.

Special accessories

Charcoal filter KF20
Remote control RM 8700
Vapour screen

Installation

Unpacking

Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the one responsible for the transport
Damages, faults and eventually missing details
should immediately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.

Placement

The hood is to be mounted on the wall.
When installed, the hood must be not less than 60
cm. above electric burners or 75 cm. above gas or
mixed-fuel burners (fig. 7).

Electrical connection

Safety warnings for the electrician
Before connecting the appliance to the power
supply, check that the voltage indicated on the
rating plate corresponds to the mains power supply
available. Appliances fitted with a plug can be
connected to any standard power socket within
easy access.
Should it be necessary to provide a fixed
connection, the hood must only be installed by an
electrician authorised by the local electricity board.
When installing, an omnipolar disconnector with a
distance of at least 3 mm between contacts must
be provided.
This disconnector may be for example a switch,
fuses (plug fuses must be removed from the fuse
66-112 cm (filter version 78-122)
89,8 cm (59,8 with vapour screen SM 8060 or SM 8062)
50 cm
2 x 20 W
1
210 W
942 120 600
942 120 658
see page 38
Fig. 7
box, fault current switches and remote switches
with a distance of over 3 mm between contacts.
The manufacture declines all responsibility for
malfunctions resulting from failure to comply with
the above instructions.
If the power socket is applied directly above the
hood this gives two advantages:
1. the socket is not visible.
2. the appliance can be disconnected at need
merely be removing the plug.
Electrical connection
220-240 V – by means of fixed power cable with
plug.
(Fixed connection of the appliance must only be
carried out by an authorised electrician.)
35
Min
Min
75 cm
60 cm