Atlantic Ultraviolet MIN-6 Manuale d'uso - Pagina 13
Sfoglia online o scarica il pdf Manuale d'uso per Sistemi di filtrazione dell'acqua Atlantic Ultraviolet MIN-6. Atlantic Ultraviolet MIN-6 16. Germicidal ultraviolet water purifiers
Anche per Atlantic Ultraviolet MIN-6: Manuale d'uso (16 pagine), Manuale d'uso (20 pagine)
TROUBLESHOOTING
Always disconnect power to the water purifier before performing any service or maintenance.
IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel.
Problem
Purifier not operating
Water leaking from purifier
Poor purifier
disinfection performance
Ballast No. 10-0508B and 10-0504B have Lamp-Out Protection
If power is applied to the ballast without a lamp connected to the circuit or if the lamp fails, the ballast's lamp-out protection
will prevent the ballast from operating, and a red LED light will illuminate and audio alarm will sound. To reset: disconnect the
ballast from power and reconnect or replace the lamp. The ballast must remain disconnected from power for (2) minutes to
reset. After 2 minutes restore input power, ballast should resume proper operation.
The equipment that this ballast is used with requires connection to a known good ground. It is the User's
responsibility to ensure that their equipment is properly grounded in compliance with the National Electrical Code and any
applicable local codes. Equipment wiring and hook up should be performed by a qualified, licensed electrician. Failure to comply
with this requirement could result in serious injury or death.
Table 3 – Troubleshooting
Possible Cause
No electrical power
Cracked or broken quartz sleeve
Quartz sleeve sealing O-Ring(s)
worn, damaged
Poor, or loose, connections
or fittings
Quartz sleeve fouled
Germicidal Lamp
STER-L-RAY
®
output depreciating
STER-L-RAY
Germicidal Lamp
®
not functioning
Low input voltage
Change in water quality
Corrective Action
Verify that the purifier is connected to a live
power source.
Shut down purifier, drain, and replace quartz sleeve.
See "Replacement of Broken Quartz Sleeve" in the
"Maintenance" section.
Shut down purifier, drain, and remove static gland
nut, replace sealing O-Ring. See "Quartz Sleeve
Installation, Cleaning, or Replacement" in the
"Maintenance" section.
Tighten suspect connection or fitting; or shut down
purifier, drain, and remove fitting or connection. Clean
threads; reapply thread sealing tape and reinstall.
Clean quartz sleeve, see "Quartz Sleeve Installation,
Cleaning, or Replacement" Section.
Replace lamp, as it nears its end of life (EOL).
See "Lamp Installation or Replacement" in the
"Maintenance" section.
Replace lamp. See "Lamp Installation or
Replacement" in the "Maintenance" section.
Verify input voltage to purifier.
Have water tested to confirm that it does not exceed
maximum recommended concentration levels for use
with this purifier.
13