1. INFRARED HEATER THEORY
Far-infrared radiant heaters are produced with unique design and manufacturing technique. Using
a specially coated aluminium panel, the heat generated by the heating element is transferred
radiantly to people and objects with maximum efficiency. The heat radiated from the panel surface,
is absorbed by people, walls, floors, furniture etc.
Infrared heating will not lead to air movement, making the air cleaner, as dust and particles are not
disturbed and circulated. Traditional convection heating relies on air movement to distribute the
heat. The air remains less humid and gives you a sense of fresh and comfortable warmth, similar
to the warmth felt from the sun.
2. PERFORMANCE FEATURES
Comfortable : No wind, light or odor will be produced during the running of this product, so the
indoor air is clean without floating dust.
Energy - saving : High heat generation and excellent heat distribution, use less energy than
traditional heating methods.
Reliable : The indoor temperature can be adjusted freely, without being limited by seasonal temperatures.
Physical therapy : The heat radiant can change body microcirculation and cell organization under the
skin producing resonance, cleaning the barrier of microcirculation, adjusting and balancing the nervous
system, promoting metabolism and increasing body physical power. It is very good for people's health.
3. WORKING CONDITIONS
Ambient temperature : -30 ⁰C ÷ +30 ⁰C
Rated voltage : 220 ÷ 240V
Rated frequency : 50 ÷ 60 Hz
Relative humidity : less than 95%
4. INSTALLATION REQUIREMENTS
1. Qualified installer :
The installation must be carried out by trained personnel.
2. Installation conditions :
(I) Supply voltage fluctuation range should be within ± 10%. If not, please revise before installation.
(II) If there is serious security risk within the user's electrical network, the installation must not
proceed, until all problems are resolved.
(III) All electrical wiring must be equipped with earth leakage protection devises and master switch.
(IV) Ground wiring must be connected to the building's grounding device. If not, please consult with
a professional installer. Do not connect ground wires to gas pipes, water pipes, lightning rods or
telephone ground wiring.
Model
AHB 18 B
AHB 24 B
AHB 32 B
Rated Current
Power
[A]
[W]
1.800
7,8
2.400
10,4
3.200
13,9
Infrared Heater AHB
Infrared Heater AHB
Voltage
[V]
220 ÷ 240
220 ÷ 240
220 ÷ 240
Cable length
[mm]
2.000
2.000
500
3