Bose FreeSpace DS 100SE Scheda tecnica - Pagina 6
Sfoglia online o scarica il pdf Scheda tecnica per Altoparlanti Bose FreeSpace DS 100SE. Bose FreeSpace DS 100SE 8. With ceiling mount bracket
Anche per Bose FreeSpace DS 100SE: Manuale d'uso (32 pagine), Manuale di installazione (17 pagine), Manuale di installazione (22 pagine), Manuale di progettazione (4 pagine), Manuale di servizio (21 pagine)
FreeSpace
®
DS 100SE
Loudspeakers
Engineers' and Architects'
Specifications
Each loudspeaker shall be a 100-watt, ported
loudspeaker system utilizing two 2.25" (57mm)
mid-high frequency drivers mounted vertically
on a rotatable, faceted baffle and a separate
5.25" (133mm) woofer. The loudspeaker shall
be used for installation on walls and other flat,
solid surfaces.
Each loudspeaker shall have a nominal rated
impedance of 8 ohms and shall be wired
in parallel with a line voltage matching
(step-down) transformer with an accessible,
front-mounted level selector appropriate for
setting various output taps. The loudspeaker
input connections will allow for direct connection
to either 70V, 100V or low-impedance amplifiers.
Exposed cosmetic surfaces of the loudspeaker
shall be paintable, and the acoustically
transparent grille component shall be
formed of powder-coated steel.
Each loudspeaker shall have a bandwidth of
65 Hz – 16 kHz and a maximum acoustic output
of 105 dB-SPL referenced to a full bandwidth
pink noise input at 1 meter at the loudspeaker's
rated power. The input connection shall consist
of a three-position barrier connector on the
included mounting bracket. Each loudspeaker
shall be wired to the mounting bracket via
a 4-pin, pre-wired connector.
Power settings available shall be: 12.5W, 25W,
50W, 100W @ 70V; 25W, 50W, 100W @ 100V;
and 100W @ 8Ω (when referenced to IEC noise
for 100 hours). The nominal dispersion shall be
180° H x 75° V at -6 dB (average 1 – 4 kHz).
When used with optional junction boxes,
which include a pre-wired ceramic connector
and a thermal fuse, the loudspeaker shall meet
numerous standards for combination music
and evacuation systems around the world.
The loudspeakers shall be the Bose
DS 100SE loudspeakers.
6 6
O O F F
8 8
p r o . B o s e . c o m
Safety and Regulatory Compliance
The FreeSpace DS 100SE loudspeakers have
passed extensive testing and comply with the
following specifications and uses:
Listed to ANSI/UL 1480-2005
• Fire Protective Signaling Use – UL Category
UUMW, File Number S 3241.
Control Number 42S9 when installed with
a junction box (on-wall or in-wall).
Not for use with DC-supervised systems.
• General Purpose Use – UL Category UEAY,
File Number S 5591 Control Number 3N89.
• The DS 100SE is suitable for use outdoors in
wet locations.
• Suitable for installation using Class 1, Class 2
or Class 3 wiring methods in accordance
with NFPA 70, National Electric Code, 2002,
Article 640.
• Suitable for use with fire alarm circuit wiring
methods in accordance with NFPA 70,
National Electric Code, 2002, Article 760.
• EMC Directive 89/336/EEC and Article 10 (1)
of the directive, EN50081-1 and EN50082-1
as signified by the CE mark.
The DS 100SE loudspeakers also have been
designed to the requirements defined in the
following European regulatory specification
for combination systems:
• British Standard Code of Practice BS 5839, Part 8.
• Tested to IEC60268-5.
Limited Warranty
The FreeSpace DS 100SE loudspeakers are covered
by a five-year transferable limited warranty.
FreeSpace
®
®