DROPSA GRIP Manuale d'uso e manutenzione - Pagina 4

Sfoglia online o scarica il pdf Manuale d'uso e manutenzione per Sistemi di lubrificazione DROPSA GRIP. DROPSA GRIP 9.

6.3 MOUNTING OF THE KIT FOR ADDITIONAL MIXING BASE
The mini-pumps are mounted on the mixer bases utilizing two securing screws.
Particular attention should be paid to the correct positioning of the o-rings between the mini-pump and the
mixer base (see diagram below).
To install a new unit proceed as follows:
1. Empty the tank of oil.
2. Disconnect the air supply and unscrew the connections on the base (codes: 323061-14071-19584-1655522-
641709. (
FIGURE
3. Connect the new base (Part n. 3132861 ore Part N. 3133265) tightening the two securing screws supplied
(cod. 14101), paying particular attention to the alignment and positioning of the seals (
kit is independently controlled but air is connected to the first base.
4. Reattach the connections to the new base (
3132861 – Pneumatic Kit
6.4 HYDRAULIC CONNECTIONS
The only connection to be undertaken is that of the individual pumps, provided with push-in connections, to the
lubrication point. The tubing must be in Ø 4 mm (0.16 in.) nylon (obtainable from Dropsa).
6.5 PNEUMATIC CONNECTIONS
Connect the air input to the push-in connector utilizing Ø 6 mm (0.23 in.) nylon tubing both for the pump and the
mixer, and provide a stop valve to permit shutting off the supply.
NOTE: After all connecting up has been completed ensure the tubing and
cables are protected from impacts and are suitably secured.
1)
Fig. 1
3133265 – Manual Kit
Fig. 2
3).
FIGURE
NOTE: The two elements with code
641709 e 3232061 must be fastened
using not-aerobic liquid sealant.
2). Note: every
FIGURE
Fig. 3
4