DROPSA GRIP Manuale d'uso e manutenzione - Pagina 5

Sfoglia online o scarica il pdf Manuale d'uso e manutenzione per Sistemi di lubrificazione DROPSA GRIP. DROPSA GRIP 9.

7. INSTRUCTIONS FOR USE

7.1 STARTING THE GRIP PANEL
Before using the GRIP panel, it is necessary to carry out some preliminary checks:
check the integrity of the equipment
-
check that the pneumatic connections have been effected correctly
-
vent the residual air from the pump using the vent screw, located at the center of the securing screws, until
-
lubricant exits (retighten the vent screw without using excessive force).
to facilitate the venting, regulate the pumps to maximum flow and operate for some cycles.
-
7.3 REGULATING THE GRIP PANEL:
GRIP WITH TIMER:
Air Regulation:
Turn the screw (1) to regulate the air flow. Clockwise
rotation reduces the air flow. Antilockwise rotation
increases the air flow.
Only Oil working mode:
Turn the screw (1) rotating it completely clockwise to
close the air flow. The pump works now only with oil.
Excluding lubricant delivery
from an individual pump:
Unscrew (anticlockwise) the red cap (2) at the end of
the pump to its stop, so completely blocking off the
delivery.
Regulating Pneumatic timer:
Turn clockwise the screw (3) to increase pause
between lubrication cicles. Turn it anticlockwise to
reduce the pause time.
Regulating lubrication delivery flow :
Use the red cap (2) to determine the nominal flow of
the individual pump.
Completely unscrew the pump red regulating cap (0
mm³ flow) turn clockwise for 1.5 turns (min. flow 5
mm³) after which every turn corresponds to an
increase in flow of 5 mm³ until reaching 30 mm³ at the
th
7
turn. (see table on the next page)
GRIP MANUAL:
Manual Regulation:
Press and release the push-button (4) to lubricate.
FLOW (mm³ / stroke)
0 = no pump delivery
5
30
25
20
15
10
5
2. Regulating
Cap for
Lubrication
3. Regulating screw
for pneumatic timer
4. Push-button
for lubricating
TURNS
Completely unscrewed
1. Regulating
screw for Air
6.5
5.5
4.5
3.5
2.5
1.5