Elektra Beckum 170 - 230 Amp Models Istruzioni per l'uso - Pagina 3
Sfoglia online o scarica il pdf Istruzioni per l'uso per Sistema di saldatura Elektra Beckum 170 - 230 Amp Models. Elektra Beckum 170 - 230 Amp Models 17. Soudure semiautomatiques mig/mag 170 - 230
Anche per Elektra Beckum 170 - 230 Amp Models: (Francese) Avviso di utilizzo (18 pagine)
- 1. Table of Contents
- 2. User Responsibility
- 3. Specifications
- 4. Regulations for the Prevention of Accidents
- 5. Welding Output
- 6. Operation
- 7. Installing the Wire Spool
- 8. Welding Stainless Steel and Aluminium
- 9. Practical Hints for MIG Welding
- 10. Maintenance
- 11. Trouble Shooting
- 12. Spare Parts List and Accessoires
Welding range
Open-circuit voltage
No-load voltage
Input capacity
Mains 50/60 Hz AC
Frequency
Welding steps
Wire diameter
Weldable material
Duty cycle (25°c/ 40°C )
100% (25°c/ 40°C )
Mains fuse
Cooling
Protection class
Isulation class
Welding gun assembly
Dimensions l x w x h
Weight
StandardScope of delivery:
regulator for shielding gas, earth clamp, wire brush and nozzle anti-clogging spray.
delivery:
2
Regulations for the Prevention of Accidents
Know the applicable regulations for electric arc welding and strictly adhere to.
Safety Instructions
●
Protection against electrical accidents
- Welding cables are to be firmly connected to ensure proper conducting capacity
- Mains cord and welding cables are to be protected against damages.
- Replace damaged mains cords with genuine Elektra Beckum parts only.
- Place welding gun onto insulating backing during short work break.
- For longer breaks switch off machine.
- When welding, wear dry and insulating gloves and shoes.
- For maintenance and repair work disconnect from power mains.
●
Protection against UV rays, burns and fumes
- Wear protective clothing to prevent burns (sleeved gloves, welding apron etc.)
- Always use a welding visor.
- Screen off work place to protect other persons working nearby against UV rays.
- Welding material having a polluted or contaminated surface may generate toxic fumes. Clean surface before
welding.
- Zinc-plated or galvanized material should not be welded as zinc fumes are highly toxic.
MIG/MAG
180/35 ET
Combi
25 - 180 A
15.3 - 23 V
17.5 - 33 V
3.6/4.6 kVA
1 ~ 230 V/2 ~ 400 V
50-60 Hz
6
0.6 - 0.8 mm
0.5 - 6 mm
180 A 35%/25%
100 A/70A
T 16 A
F
IP 21
F
SB 15/2
840x410x580
68 kg
Welding machine with MIG/MAG torch c/w contact tip and gas shroud, pressure
MIG/MAG
200/35 ET
25 - 200 A
15.3 - 24 V
21 - 34 V
6 kVA
3 ~ 400 V
50-60 Hz
6
1,0 mm
0.5 - 7 mm
200 A 35%725%
110 A/75A
T 16 A
F
IP 21
F
SB 15/2
840x410x580
75 kg
MIG/MAG
230/40 ET
25 - 230 A
15.3 - 25,5 V
19 - 34 V
6.5 kVA
3 ~ 400 V
50-60 Hz
6
0.6 - 1.0 mm
0.6 - 9 mm
230 A 40%/30%
140 A/100A
T 16 A
F
IP 21
F
SB 25/2
840x410x580
81HAM kg