Absolare Integrated Amplifier Manuale d'uso - Pagina 9
Sfoglia online o scarica il pdf Manuale d'uso per Amplificatore Absolare Integrated Amplifier. Absolare Integrated Amplifier 11.
7. Troubleshooting and Maintenance
Surface of the unit is dirty
No power light
Remote control is not working
Power light is on, tube heaters are
glowing, but no sound
Noise / hum in the sound
If the problem is persistent, contact your nearest ABSOLARE dealer.
8. Technical Specifications
- Input Sensitivity: 0.5 Volts (Balanced Version 2 Volts)
- Tubes: 2 x (12AU7 / ECC82) – every unit supplied with select NOS tubes
- Inputs: 4 RCA with Single-Ended / 4 XLR with Balanced model
- Input impedance: 100 kΩ
- Output Power: 200 Watts min. @ 4 Ω, 150 Watts min. @ 8 Ω
- 48-step attenuator- IR Remote Control
- Gain: 37 dB
- Bandwidth: 20Hz -20kHz within +/- 0.2dB, 15 Hz – 30 KHz +/- 1.0 dB
- Dimensions: 38.2 x 67.4 x 20 cm / 15" x 26.4" x 7.9" (W x D x H), excl. feet
- Weight: 30 kg
ABSOLARE Integrated Amplifier User Manual 1.2
Clean with a slightly damp cloth.
- Check AC line voltage
- Check the main fuse
- Check the angle, see section (6.2)
- Check the battery of the remote-control
unit
- Check the input cables, speaker cables
and source
- Check input selector
- Check if tube(s) are defective
- Check grounding of power, input cables
and source
9