DSC HS2LCDWF v1.0 Manuale di istruzioni per l'installazione - Pagina 6
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Tastiera DSC HS2LCDWF v1.0. DSC HS2LCDWF v1.0 9. Wireless keypad
Keypad Function Keys
Please see your system installation manual for more details on the function key
options below.
[00] - Null
[16] - Quick Exit
[01] - Disarm
[17] - Arm Interior
[02] - Instant Stay
[18]-[20] - For Future Use [52] - [P] Key Alarm
Arm
[03] - Stay Arm
[21] - Command Output 1 [53] - [92] For Future Use
[04] - Away Arm
[22] - Command Output 2
[05] - [*][9] No-Entry
[23] - Command Output 3
Arm
[06] - Chime ON/
[24] - Command Output 4
OFF
[07] - System Test
[25]-[28] - For Future Use
[29] - Bypass Group
[08] - For Future Use
Recall
[09] - Night Arm
[30] - Quick Bypass
[10] - For Future
[31] - For Future Use
Use
[11] - Away Arm no
[32] - For Future Use
Entry
[12] - Global Stay
[33] - Bypass Recall
Arm
[13] - Global Away
[34] - For Future Use
Arm
[14] - Global Dis-
[35] - For Future Use
arming
[36] - Reactivate Stay/
[15] - For Future Use
Away and Night Zones
Keypad Programming
Enter keypad programming by entering Installer Programming, then Section [861] to
[876], which apply to keypads 1-16.
[860] Keypad Slot Number
This is not for programming; the two-digit slot number is displayed for information
only.
[37]-[50] For Future Use
[51]- [A] Key Alarm
[861]-[876] Keypad Programming Sections
[000] Address of Partition
Upon selecting [000], a 2-digit entry is required to assign the keypad to a partition.
Entering 00 assigns the keypad as global. Valid entries are 00-32. The default is 01.
[001]-[005] Function Key 1-5 Assignment
[011] Keypad Input/Output Programming
Default
Zone or PGM
Number
00
[012] Local PGM Output Pulse Activation Time
Minutes (00-99)
I _ ____I _ ____I
Seconds (00-99)
I _ ____I _ ____I
[021] First Keypad Options
Default
Opt.
ON
ON
I_____I
1
Fire Key Enabled
ON
I_____I
2
Medical Key Enabled
ON
I_____I
3
Panic Key Enabled
Display Access Code
ON
I_____I
4
When Programming
OFF I_____I
5
For Future Use
OFF I_____I
6
For Future Use
OFF I_____I
7
For Future Use
OFF I_____I
8
For Future Use
[022] Second Keypad Options
Default
Opt. ON
ON
I_____I
1
Local Clock Display ON
Local Clock Displays 24-hr
OFF
I_____I
2
Time
ON
I_____I
3
Auto Alarm Scroll ON
OFF
I_____I
4
For Future Use
OFF
I_____I
5
Power LED Enabled
I_____I_____I_____I
OFF
Fire Key Disabled
Medical Key Disabled
Panic Key Disabled
Display X's When Pro-
gramming Access
Codes
For Future Use
For Future Use
For Future Use
For Future Use
OFF
Local Clock Display
OFF
Local Clock Displays
AM/PM
Auto Alarm Scroll OFF
For Future Use
Power LED Disabled