DSC Misterhouse PC5401 Istruzioni per l'installazione
Sfoglia online o scarica il pdf Istruzioni per l'installazione per Unità di controllo DSC Misterhouse PC5401. DSC Misterhouse PC5401 2. Data interface module
The PC5401 Data Interface Module can be used to quickly and easily communicate
with PowerSeries™ panels through a standard RS-232 serial connection. (See the
PC5401 Developer's Guide for more information on communicating with the PC5401
module) at www.dsc.com/support/installation manuals.
Specifications
Module Current Draw: 35 mA
Terminal Connections
KEYBUS - The 4-wire KEYBUS connection is used by the panel to communicate
with the module. Connect the RED, BLK, YEL and GRN terminals to the KEYBUS
terminals on a PowerSeries™ panel.
DB9 – Requires a "straight-through" RS-232 cable. Only the RX, TX and GND
connections are used. Note: cable should not exceed 50 ft at 9600 BAUD (consult
RS-232 Signaling Standard for more information)
To Connect Module to a Control Panel
This module can be installed in any of the following enclosures: PC4003C,
PC5003C, HS-CAB1000, HS-CAB3000, HS-CAB4000.
1. Connect module to the KEYBUS (with the panel powered down).
2. Select desired BAUD using JP1-3 (default is 9600 BAUD, see Table 1).
2. Connect an RS-232 cable to the application.
3. Power up the system.
Figure 1
To Panel
Notes:
• The PC5401 is designed to be installed by SERVICE PERSONS only.
• These instructions shall be used in conjunction with the applicable
Installation Instructions of the used PowerSeries™ alarm controller.
Installation Instructions
JP1
JP2
JP3
RED
BLK
YEL GRN
RS-232
To Application
PC54O1
Data Interface Module
Version 1.O