DSM VF-150 OEM Manuale d'uso - Pagina 2

Sfoglia online o scarica il pdf Manuale d'uso per Amplificatore DSM VF-150 OEM. DSM VF-150 OEM 7.

Please review the following points for both personal and equipment safety while operating the
linear piezoelectric amplifier.
HIGH ENERGY/VOLTAGE WARNINGS
Exercise caution when using amplifiers. High energy levels can be
stored at the output voltage terminals on all amplifiers in normal
operations. In addition, potentially lethal voltages exist in the power
circuit and the "output" connector. Filter capacitors store potentially
dangerous energy for some time after power is removed.
OPERATING AND SERVICES PRECAUTIONS
Operate the amplifier in an environment free of flammable gases or fumes. Do not use substitute
parts or make any unauthorized modifications to the amplifier to ensure that its safety features
are not degraded. Contact DSM for service and repair assistance.

SPECIFICATIONS

• Typical Output Voltages:
• Maximum Continuous Current:
• Maximum Peak Current:
• Gain V/V
• Dimensions: L x W x H
• Dimensions: L x W x H with heat sink
• Amplifier bandwidth:
• Electrical Noise on Output:
• Short circuit, over-current, and over-temperature protection
• Connectors:
VF-150 OEM
-100 to +100 V
-40 to +200 V
-30 to +150 V
-20 to +120 V
Output range will be V
150 mA (Capacitive load)
300 mA (Capacitive load)
~58 +/- 5% (see AGA command)
2.0" x 1.0" x 0.5" (50.8mm x 25.4mm x 12.7mm)
2.0" x 1.0" x 1.0" (50.8mm x 25.4mm x 25.4mm)
~10 kHz (-3dB)
~1mVrms (power supply dependent)
FCI 10106813-021112LF
FCI 10106813-041112L
 
Hardware Version V131028
CAUTION
RISK OF DANGER
+ 5V to V
Neg Rail
114 Southeast Parkway Ct.
Ste 160
Franklin, TN 37064
Tel: 615/595-6665
Fax: 615/595-6610
– 5V
Pos Rail
1