Note 6. D is the Derivative Time, measured in seconds. The derivative action
contributes to the output power based on the rate of temperature change. A
larger D value results in stronger derivative action. The derivative action
adjusts the output based on the rate of change rather than the net amount of
change. This allows the controller to respond more promptly.
Note 7. T is the Control Cycle Time, measured in seconds. By default, the
Control Cycle T is set to 15 seconds. This parameter determines how
frequently the controller updates the output. For instance, if the current output
is 18%, and the controller calculates that it needs to increase the output to
22%, it will wait till the end of the current control cycle. Once the next 15-
second cycle begins, the controller will adjust the output to 22%. This control
cycle applies to both the Fan Speed (FS) Control Mode and the Time
Proportional (TP) Control Mode.
Note 8. The MODE setting allows users to choose from one of the four control
modes listed below:
a)
Manual-FS: The user can manually determine the output
level; the controller adjusts the output level by changing the
fan-speed (FS).
b)
Manual-TP: The user can manually determine the output
level; the controller adjust the output level by Time
Proportional (TP) method.
c)
PID-FS: The PID algorithm determines the output level; the
controller changes the output level by adjusting the fan-speed
(FS).
d)
PID-TP: The PID algorithm determines the output level; the
controller changes the output level by Time Proportional (TP)
method.
In Fan Speed (FS) mode, the fan speed is adjusted by changing the output
voltage to the fan within the range of 4VDC to 12VDC.
In Time Proportional (TP) mode, the output level is adjusted by changing the
percentage of time that the fan will be running.
Note 9. The Save and Recall functions allow users to save or recall the P, I, D,
and Control Mode settings to/from a specified saving slot, with a total of 6 sets
available. Users can tune PID parameters and choose different Control Modes
for various cooking conditions (e.g., different smokers/grills, ambient
temperatures, or target cooking temperatures) and save them for future use.
Refer to Table 4 for the name, P, I, D, and Mode settings in each parameter
set.
The first three sets are named "BGE", "WSM22", and "WSM18", pre-tuned for
the 18.5'' Big Green Egg, 22.5" Weber Smokey Mountain, and 18.5" Weber
Smokey Mountain, respectively. The other three sets, named "4", "5", and "6",
are available for custom-tuned parameter settings. However, their names
cannot be changed.
To save current PID parameters and Control Mode, navigate to "Control
Setting", use the ▼ key to find "Save", press the SET key to make the word
"Back" flash on the right side of the screen, use ▲ or ▼ keys to select the
desired group name for saving the settings, then press the SET key again to
save the settings.
2024.01
To recall a set of parameters and Control Mode, go to "Control Setting", use
the ▼ key to find "Recall", press the SET key to make the word "Back" flash
on the right side of the screen, use ▲ or ▼ keys to select the desired group
name from which to recall the settings, then press the SET key again to recall
the settings for the current cooking process.
Table 4. The default values of the saved PID and Mode Settings.
Group #
Group Name
1
BGE
45
2
WSM22
45
3
WSM18
45
4
4
45
5
5
45
6
6
45
6.2 System Configuration
The parameters in the System Configuration menu are listed in the table
below, with details for each parameter explained in the following notes.
Table 5. Parameters in System Configuration.
Name
Description
Multi-Step Program
PRG
Mode
OL-
Open-Lid Detection
Detection
Minimum Running
FMRV
Voltage of the Fan
OUTH
Output High-Limit
OUTL
Output Low-Limit
C-F
Temperature Unit
PB1
Probe 1 Offset
PB2
Probe 2 Offset
PB3
Probe 3 Offset
Enable or Disable the
Buzzer
On-Board Buzzer
nFIL
Powerline Filter
LCD Back-Light
Brightness
Brightness
Enable Pushing
Push
Temperature Alarms to
Alarm
a Paired Mobile Device
Enable Pushing Step
Push Step
Notifications to a Paired
Mobile Device
Restore All Parameters
Reset
to Factory Default
Values
Reset Wi-Fi Module to
Reset
AP Mode (Pairing
WiFi
Mode)
Check and Update
Update
Device Firmware
Back
Back to the Main Menu
WWW.AUBERINS.COM
P
I
D
Mode
1200
75
PID-TP
1200
75
PID-FS
1400
100
PID-FS
1200
75
PID-FS
1200
75
PID-FS
1200
75
PID-FS
Range
Default
ON, OFF
OFF
ON, OFF
ON
3.0 V ~ 11.0 V
4.0
0 ~ 100 (%)
100
0 ~ 100 (%)
0
°C, °F
F
-99 ~ 100
0
-99 ~ 100
0
-99 ~ 100
0
On, Off
On
A, B, Auto
B
0 ~ 10
10
On, Off
On
On, Off
On
Yes, No
No
Yes, No
No
Yes, No
No
Note
10
11
12
13
13
14
15
15
15
16
17
18
19
20
21
22
23