DAN DRYER 244 Turbo Manuale di manutenzione e assistenza - Pagina 6
Sfoglia online o scarica il pdf Manuale di manutenzione e assistenza per Asciugatrice DAN DRYER 244 Turbo. DAN DRYER 244 Turbo 12.
Reference
Version
244-ENG
09-01-2018
Cleaning the inside of the machine
Warning !!!
During cleaning and service the hand dryer must always be disconnected from the power supply.
1.Disassemble cover by removing the two cover
screws at the bottom of the housing. Use the
special Allen key which was originally supplied
with the hand dryer.
Remove the
cover screws
2. Disassemble angle bracket by removing the
screw (A)
(A)
3. Remove the four screws (B). Disassemble the
top half of the motor housing
(B)
(B)
DAN DRYER A/S • Tåsingevej 2 • DK-8940 Randers SV • Tel: +45 86 41 57 11 • Email: [email protected]
244 DAN DRYER Turbo (with nozzle)
Maintenance and service manual
Remove the
cover screws
(B)
(B)
Document
4. Carefully lift up the motor whilst taking note
how the motor was positioned inside the
housing and how the motor wires are placed in
the protective grooves (C)
5. Disconnect motor wires from the timer unit
(appearance depends on the timer type).
Place the motor on a table upside-down.
6. Check whether carbon brushes are worn down
and need to be replaced. If so, disassemble by
removing the screws and by disconnecting
wires from carbon brush terminals.
Lang.
Page
ENG
6 of 12