Addi-Data CPCI-1710 Manuale - Pagina 10
Sfoglia online o scarica il pdf Manuale per PCI Card Addi-Data CPCI-1710. Addi-Data CPCI-1710 13. Multifunction counter board, optically isolated
Anche per Addi-Data CPCI-1710: Descrizione della funzione (15 pagine)
Function description
PCI-1710: Pulse counter
1.5.2 Connection example
Fig. 1-3: Connection example
1.6 Procedure for using the "Pulse counter" function
In order to use the "Pulse counter" function, the following steps need to be performed:
1. Program the counter value (= reload value) of the downward counter.
2. Select the edge (rising or falling) of the counter input signal that should count.
3. Define the action(s) to be performed when the counter has run down: Release interrupt; set or reset
output (only with pulse counter 0).
4. Select the counter mode (Continuous or Single mode).
5. Enable the counter via the gate bit.
www.addi-data.com
10