Sfoglia online o scarica il pdf Manuale di configurazione per Automobile Accessories Free2Move eSolutions eProWallbox Series. Free2Move eSolutions eProWallbox Series 16. Modbus rtu
GENERAL_STATUS: 40101
The address contains the status of the charging station according to IEC 61851 State Machine as
it follows:
•
0 = A1
•
1 = A2
•
2 = B1
•
3 = B2
•
4 = C1
•
5 = C2
•
6 = D1
•
7 = D2
•
8 = E
•
9 = F
OCPP_STATUS: 40102
The address contains the OCPP status of the charging station as it follows:
•
0 = Available (OCPP_Status A)
•
1 = Preparing (OCPP_Status B)
•
2 = Charging (OCPP_Status C)
•
3 = SuspendedEV (OCPP_Status D)
•
4 = SuspendedEVSE (OCPP_Status E)
•
5 = Finishing (OCPP_Status F)
•
6 = Reserved (OCPP_Status G)
•
7 = Unavailable (OCPP_Status H)
•
8 = Faulted (OCPP_Status I)
USER_CURRENT_LIMIT: 40103
The address contains the Current Limit set by the user through the App expressed in mA
LOAD_UNBALANCE_LIMITING: 40106
The address contains the status of the Current Unbalance Function:
•
0 = function disabled
•
1 = function enabled. Charging current limited by the Current Unbalance Function