GENERAL_STATUS: 40101
The address contains the status of the charging station according to IEC 61851 State Machine as
it follows:
0 = A1
1 = A2
2 = B1
3 = B2
4 = C1
5 = C2
6 = D1
7 = D2
8 = E
9 = F
OCPP_STATUS: 40102
The address contains the OCPP status of the charging station as it follows:
0 = Available (OCPP_Status A)
1 = Preparing (OCPP_Status B)
2 = Charging (OCPP_Status C)
3 = SuspendedEV (OCPP_Status D)
4 = SuspendedEVSE (OCPP_Status E)
5 = Finishing (OCPP_Status F)
6 = Reserved (OCPP_Status G)
7 = Unavailable (OCPP_Status H)
8 = Faulted (OCPP_Status I)
USER_CURRENT_LIMIT: 40103
The address contains the Current Limit set by the user through the App expressed in mA
LOAD_UNBALANCE_LIMITING: 40106
The address contains the status of the Current Unbalance Function:
0 = function disabled
1 = function enabled. Charging current limited by the Current Unbalance Function