Free2Move eSolutions eProWallbox Series Configuratiehandleiding - Pagina 9
Blader online of download pdf Configuratiehandleiding voor {categorie_naam} Free2Move eSolutions eProWallbox Series. Free2Move eSolutions eProWallbox Series 16 pagina's. Modbus rtu
BAUD_RATE: 40210
The address contains the number of transitions per second occurring on the communication line
expressed as Baud Rate:
•
4 = 115200
•
3 = 57600
•
2 = 38400
•
1 = 19200
•
0 = 9600
The default value is set to 4.
NEW_BAUD_RATE: 40211
The address is used for setting the new Baud Rate value. Insert in this field the new Baud Rate
value.
The default value is set to 4.
ACTIVATE_NEW_BAUD_RATE: 40212
The address is used for the activation of a new Baud Rate value. Enter 0x5555 to activate the
new Baud Rate value inserted in the address 40211.
DPM_ENABLED: 40400
The address contains the status of the DPM:
•
0 = disabled
•
1 = enabled
MID_METER_ENABLED: 40401
The address contains the status of the MID meter:
•
0 = disabled
•
1 = enabled (External MID meter connected)
MODBUS RTU
C o n f i g u r e a t i o n G u i d e
9