Duro Dyne SSFU Manuale d'uso - Pagina 3

Sfoglia online o scarica il pdf Manuale d'uso per Spruzzatore di vernice Duro Dyne SSFU. Duro Dyne SSFU 8. Adhesive applicator

EQUIPMENT MISUSE HAZARD
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
• This equipment is for professional use only.
• Read all instruction manuals, tags and labels before operating the equipment.
• Use the equipment only for its intended purpose. If you are not sure, call Duro Dyne's Technical Service
department at 1-800-899-3876
• Do not alter or modify this equipment.
• Check equipment daily. Repair or replace worn or damaged parts immediately.
• Do not exceed the maximum working pressure of the lowest rated component in your system. This equipment
has a 100 psi (7 bar) maximum working pressure at 100 psi (7 bar) maximum incoming air pressure.
• Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data
section of all equipment manuals. Read the fluid and solvent manufacturer's warnings.
• Do not use hoses to pull equipment.
• Route hoses away from traffic areas, sharp edges, and hot surfaces. Do not expose hoses to temperatures
above 82°C (180°F) or below -40°C (-40°F).
• Wear hearing protection when operating this equipment.
• Do not lift pressurized equipment.
• Comply with all applicable local, state, and national fire, electrical, and safety regulations.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious
injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed
• Know the specific hazards of the fluid you are
using.
Store hazardous fluid in an approved container. Dispose of haz-
ardous fluid according to all local state and national guidelines.
Always wear protective eyewear, gloves, clothing, and respira-
tor as recommended by the fluid and solvent manufacture.
Pipe and dispose of the exhaust air safely, away from people,
animals, and food handing areas. If the diaphragm fails, the fluid
is exhausted along with the air. See Air Exhaust Ventilation in
the separated pump manual 308-553.

TECHNICAL DATA

TECHNICAL DATA
Wetted Parts
Pump............. .....................Acetal/Teflon*
Spray Gun...... .....................Stainless/Aluminum
Fluid Hoses..........................Nylon
Surge Tank...........................Nylon
Fluid Regulator
Fittings
235-366...................Acetal, Carbon Steel
Tubling..................................Nylon
FIRE OR EXPLOSION HAZARD -
Improper grounding, poor ventilation, open flames,
or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
• If there is any static sparking or you feel an elec-
tric shock while using the equipment stop pumping
immediately. Do not use the equipment until you identify and
correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable
fumes from solvents or the fluid being pumped.
Pipe and dispose of the exhaust air safely, away from all
sources of ignition. If the diaphragm fails, the fluid is exhausted
along with the air.
Keep the work area free of debris, including solvent, rags, and
gasoline.
Electrically disconnect all equipment in the work area.
Extinguish all open flames or pilot lights in the work area.
Do not smoke in the work area.
Do not turn on or off any light switch in the work area while
operating or if fumes are present.
Do not operated a gasoline engine in the work area.
Maximum Fluid Working Pressure..... 100 psi (7 bar)
Maximum Operating Range.............. 15-100 psi (1-7 bar)
Pump Air Inlet Size..........................1/4 npt (f)
Pump Fluid Inlet and Outlet Size....... 3/8 npt (f)
*Sound Data
Pump sound level at 100 psi (7 bar), full flow....
.......................................................85 dB(A)
Pump sound level at 70 psi (4.8 bar)
1 gpm (3.8 lpm................................78 dB(A)
Operating Temperature Range; 40° to 150°F (4.4°-65.5° C)
*Tested to CAGI-PNEUROP-1969
3