OPERATION

OPERATION
General Information:
1 - The typical assembly and installation shown on pages 4, 5 and 6 are only a guide for selecting and in-
stalling system components.
2 - Always use genuine Duro Dyne Super Sprayfast Universal parts and accessories, available from your
Duro Dyne Distributor. Refer to the Product Data Sheet for the pump. If you supply your own accessories,
be sure they are adequately sized and pressure rated for your system.
3 - Use a compatible, liquid thread sealant or Teflon tape on all male threads. Tighten all connections firmly
to avoid air or fluid leaks. Do not over-tighten plastic threads.
Pressure Relief Procedure:
WARNING
of an injury from accidental spray from the gun, splashing fluid or moving parts, follow the
Pressure Relief Procedure whenever you:
-
Are instructed to relieve the pressure,
-
Stop spraying,
-
Check or service any of the system equipment,
-
Or install or clean the spray tips.
1.
Shut off the air to the pump.
2.
Trigger the spray gun.
3.
Open the Re-circulating Valve (see Figure-3) to relieve all fluid pressure, having a container ready to
catch the drainage.
Pump Shutdown:
WARNING
Flushing and Storage:
WARNING
Flush the Pump when necessary to prevent the fluid you are pumping from drying or freezing in the pump
and damaging it. Use a compatible solvent/mineral spirit.
Before storing the Pump, always relieve the pressure as noted at left and flush the Pump as follows:
(see Figure-2 below)
1 - Ensure the Re-Circulating Valve is in the "OFF" position.
2 - Open the Flush Fitting and secure the Flush Hose properly. Place the open end of the Flush Hose into a
container of water.
3 - Rotate Lever-A 90deg, then rotate Lever-B 90deg.
4 - Trigger the Spray Gun into another container until only clear water comes through.
5 - Store the Pump and Spray Gun properly until its next use.
Figure 2:
PRESSURIZED EQUIPMENT HAZARD
The system pressure must be manually relieved to prevent the
system from starting or spraying accidentally. To reduce the risk
To reduce the risk of serious injury whenever you are instructed to
relieve pressure, always follow the Pressure Relief Procedure.
To reduce the risk of serious injury whenever you are instructed to
relieve pressure, always follow the Pressure Relief Procedure.
TOP VIEW
Lever-A
Flush
Fitting
5
Re-Circulating
Valve
Pump
Lever-B
Flush Hose
Short Suction Tube
SIDE VIEW
Flush Hose