Datalogic IO-Link S8 Manuale di istruzioni - Pagina 7

Sfoglia online o scarica il pdf Manuale di istruzioni per Accessories Datalogic IO-Link S8. Datalogic IO-Link S8 17.

Datalogic IO-Link S8 Manuale di istruzioni
Observation / Diagnostic Parameters
Index
(dec)
0x0028 (40)
0x0041 (65)
0x0052 (82)
0x0053 (83)
0x0057 (87)
0x0024 (36)
0x0025 (37)
0x0051 (81)
0x0059 (89)
0x005A (90)
0x005E (94)
Teach-in Parameters
Index
(dec)
0x003A (58)
0x003B (59)
0x003C (60)
0x003D (61)
0x003E (62)
0x003F (63)
0x0040 (64)
*RO = read only, WO = write only, R/W = read/write
Parameter
Subindex
Lenght
Value/Range
Object Name
(offset)
Process Data
1 octet
Input
Analog Signal
2 octets
2 octets
1(64)
2(48)
2 octets
Device
2 octets
3(32)
Temperature
2 octets
4(16)
2 octets
5(0)
Device
2 octets
1(16)
Temperature
Threshold
2 octets
2(0)
4 octets
1(64)
Operating Hours
4 octets
2(32)
0...(2^32)-1
3(0)
4 octets
0x00 → Device is operating properly
0x01 → Maintenance Required
Device Status
1 octet
0x02 → Out of specification
0x03 → Functional Check
0x04 → Failure
Detailed Device
3 octets
Status
0x00 = Emitter OFF
Emitter Status
1 octet
0x01 = Emitter ON
0x01 = Red emission
RGB selection
1 octet
0x02 = Green emission
(W03)
0x03 = Blue emission
Frequency
0x00 = 2 kHz (default)
1 octet
Selection (U03)
0x01 = 500 Hz
0 = low (default T53)
Delta (B53, T53)
1 octet
1 = medium (default B53)
2 = high
Parameter
Subindex
Lenght
Value/Range
Object Name
(offset)
0x00 = SSC1 (default, C/Q pin and DO
TI Select
1 octet
pin)
Teach-in State
1(0)
TI Result
1 octet
2(4)
Flag SP1 TP1
3(5)
Flag SP2 TP1
U03: 220...1950 (default = 512)
W03: 220...1950 (default = 1280)
2 octets
1(16)
T53: 181...1950 (default = 196)
SSC1 Param
B53: 215...1950 (default = 215)
2 octets
2(0)
Not used
1 octet
1(24)
0x00: High Active (default U03)
0x01: Low Active (default W03, T53, B53)
1 octet
2(16)
0x01: Single Point (default)
SSC1 Config
0 = low hysteresis (default)
2 octets
3(0)
1 = medium hysteresis
2 = high hysteresis
U03: 220...1950 (default = 512)
W03: 220...1950 (default = 1280)
2 octets
1(16)
T53: 181...1950 (default = 196)
SSC2 Param
B53: 215...1950 (default = 215)
2 octets
2(0)
Non used
1 octet
1(24)
0x00: High Active (default W03, T53, B53)
0x01: Low Active (default U03)
1 octet
2(16)
0x01: Single Point (default)
SSC2 Config
0 = low hysteresis (default)
2 octets
3(0)
1 = medium hysteresis
2 = high hysteresis
0 ..7 Sensitivity
U03 default = 3
Sensitivity
1 octet
W03 default = 5
selection
T53 default = 7
B53 default = 7
Description
Data Type
Device
Read last valid Process Data Input from PDin channel
specific
Read analog signal
UIntegerT
Device temperature actual
IntegerT
Device min. temperature since powerup
IntegerT
Device max. temperature since powerup
IntegerT
IntegerT
Device min. temperature during lifetime
IntegerT
Device max. temperature during lifetime
Device min. temperature threshold
IntegerT
IntegerT
Device max. temperature threshold
UIntegerT
Operating Hours: device operating hours. Not resettable by user.
Operating Hours Maintenance: device operating hours, reset on
UIntegerT
system command "Confirm Maintenance".
Operating Hours Power Up: Time in hours since power up.
UIntegerT
Contains current status of the device
UIntegerT
Information about currently pending Events.
UIntegerT
Implemented as dynamic list.
Contains current statuts of the emitter
BooleanT
Select emission type
UIntegerT
Select frequency
UIntegerT
Set the delta between the signal measured on the reflector and the
UIntegerT
thresholds. "Low" is preferred for transparent object detection.
Description
Data Type
Selection for Teach-in channel (volatile)
UIntegerT
UIntegerT
See IO-Link Smart Sensor Profile
BooleanT
BooleanT
Switching threshold
UIntegerT
UIntegerT
UIntegerT
C/Q pin configuration
UIntegerT
Switching threshold
UIntegerT
UIntegerT
UIntegerT
DO pin configuration
UIntegerT
Sensitivity
UIntegerT
Access*
Remark
RO
RO
RO
RO
RO
RO
RO
Saved in non-volatile memory every
R/W
hour. Events are generated if the device
temperature exceeds the thresholds.
RO
RO
RO
RO
RO
RO
R/W
Saved in non-volatile memory
R/W
R/W
Saved in non-volatile memory
Access*
Remark
C/Q and DO outputs are antivalent.
R/W
Teach SSC1 equals to teach SSC2
RO
Saved in non-volatile memory
Setting a higher threshold
R/W
reduces the operating distance
progressively to 0 (output always
active)
R/W
Saved in non-volatile memory
Saved in non-volatile memory
Setting a higher threshold
R/W
reduces the operating distance
progressively to 0 (output always
active)
R/W
Saved in non-volatile memory
R/W
Saved in non-volatile memory