PROCESS DATA
Process Data Input
7
6
5
4
Not used
ALARM (B53)
DEVICE VARIANT COLLECTION
Product name
Product ID
Product text
S8-PR-5-W03-0Z
00004
Contrast sensor
S8-PR-5-T53-0Z
00005
Reflex transparent
S8-PR-5-B53-OZ
00006
Reflex polarized laser
S8-PR-5-U03-OZ
00007
Luminescence sensor
EXTENDED PARAMETERS
Switch Counter
Index
Parameter
Subindex
Lenght
Value/Range
(dec)
Object Name
(offset)
0: OFF (default)
1: Counter (STATIC)
1(24)
2: Counter (AUTO)
1 octet
Switch counter
0x00B6 (182)
1 octet
settings
0: Output Rising Edge (default)
2 octets
2(16)
1: Output Falling Edge
3(0)
0-65535 (default = 0)
0: counting UP (default)
1(16)
1: counting DOWN
Switch counter
1 octet
0x00B7 (183)
2: counting INACTIVE
values
2 octets
2(0)
-32,768..32,767
Index
Parameter
Value
Lenght
Description
(dec)
Object Name
(dec)
0x0002 (2)
Reset counter
1 octet
0xA0(160)
Reset counter value
0x0002 (2)
Enable counter UP
1 octet
0xA1(161)
Enable counter and start count UP (counter value is not reset. Reset counter command to zero the value)
Enable counter
0x0002 (2)
1 octet
0xA2(162)
Enable counter and start count DOWN (counter value is not reset. Reset counter command to zero the value)
DOWN
0x0002 (2)
Stop counter
1 octet
0xA3(163)
Freeze the counting functions (all commutations are neglected: counting INACTIVE). Enable counter to resume the counting function.
Byte 0
3
2
1
COUNTER EXCEED
TEACH-IN
SSC2 (DO pin)
SSC1 (C/Q pin)
THRESHOLDS
Description
Mode
Trigger counter
Threshold counter
Counting direction
Switch counter value
0
Data Type
Access*
Remark
Saved in non-volatile memory.
UIntergerT
RW
Stop or reset the running counter
before changing configuration, then
re-enable the counter with Set counter
Boolean
RW
commands.
*Rising and falling egdes are referred
to DO pin.
UIntegerT
RW
UIntegerT
RO
IntegerT
RO
Access
WO
WO
WO
WO