dymax BlueWave 50 Manuale operativo - Pagina 10

Sfoglia online o scarica il pdf Manuale operativo per Apparecchiature di illuminazione dymax BlueWave 50. dymax BlueWave 50 20. Uv light-curing spot lamp system

INSTALLATION AND SYSTEM INTERCONNECT

1. Connect the Power Cord to the Power Receptacle on the rear of the
unit and plug the Power Cord into a grounded wall outlet.
2. Connect the Footswitch to the Footswitch Connection (Figure 4) in
the rear of the unit.
3. Remove the protective cover from the BlueWave
Mount (Figure 5).
NOTE:
Always have a Lightguide or the protective cap engaged in
the Lightguide Mount. UV light can escape when the Shutter is
activated.
4. Remove the protective end caps from the Lightguide. Visually
inspect the two ends of the Lightguide to verify that no foreign
material is present. The ends of a DYMAX liquid-filled Lightguide can
be cleaned with isopropyl alcohol as required to remove foreign
material and deposition from outgassing.
5. Insert the large end of the Lightguide into the Lightguide Mount until
it snaps into place (Figure 6).
6. If desired, the Lightguide may be fastened into place by lightly
tightening the securing setscrew installed in the Lightguide Mount
(Figure 6). A hex wrench is provided with the BlueWave 50 for this
purpose. The setscrew should be tightened gently to prevent
damaging the Lightguide.
IMPORTANT!
To ensure that proper output of the system is
obtained, be sure to completely insert the Lightguide into the
Lightguide Mount prior to tightening the Setscrew. Be sure to lightly
tighten the Setscrew to ensure the Lightguide remains in place
during use.
NOTE:
Multi-leg Lightguides should be balanced by rotating the
Lightguide to obtain the desired UV intensity of each leg before
tightening the setscrew.
7. Turn the BlueWave 50's Power Switch on.
8. Allow the Bulb to warm up 4-5 minutes to obtain the maximum light
output.
CAUTION:
This is an arc, not a filament Bulb. Once ignited, it must
be left on for a minimum of 10 minutes to fully vaporize elements in
the Bulb. If not, the Bulb may be difficult to re-ignite. Each re-
ignition increases the rate of Bulb degradation.
NOTE:
The Bulb must cool before it can be re-ignited. Should the
Bulb extinguish, leave the Power Switch on. This operates the
Cooling Fan and allows the Bulb to re-light when it has cooled
sufficiently. If the Bulb fails to ignite, refer to the Troubleshooting
section of this manual. Bulb life is reduced approximately one hour
each time the Bulb is switched on and off. Avoid repeated cycles
that shorten Bulb life by leaving the unit on through breaks.
10
®
50's Lightguide
Footswitch
Connection
Power
Receptacle
Power Cord
Figure 4. Cable Connection,
BlueWave 50 Rear Panel
Figure 5. Lightguide Mount
Protective Cover Installed (left);
Protective Cover Removed (right)
Figure 6. Insert Lightguide into
Lightguide Mount
®
BlueWave
50 Light-Curing Spot Lamp