dymax BlueWave 200 Manuale d'uso - Pagina 6

Sfoglia online o scarica il pdf Manuale d'uso per Apparecchiature mediche dymax BlueWave 200. dymax BlueWave 200 16. Handheld diaphragm valve
Anche per dymax BlueWave 200: Istruzioni per l'avvio rapido (2 pagine), Istruzioni per l'avvio rapido (2 pagine), Istruzioni per l'avvio rapido (2 pagine), Istruzioni per l'avvio rapido (2 pagine)

6
Model 200 Dispensing Valve User Guide
curable adhesives, cyanoacrylates, and anaerobic adhesives. This dispensing valve can
be used for a variety of applications including dot, bead, and potting applications.
Component Description
The Model 200 is comprised of two main sections — the Fluid Section and the Piston
and Lever Section, which are housed all in one Body. The Body of the Fluid Section is
constructed of Delrin® and contains a Teflon® Diaphragm. The Fluid Section and the
Piston and Lever Section are separated by a Diaphragm that is clamped in between the
two sections. The Piston and Lever Section is comprised of an aluminum Top-Cap that
houses a Spring-Loaded Piston. This Piston presses against the Diaphragm to keep the
Valve in the closed position. When the Lever is depressed, the Piston raises off the
Diaphragm allowing the Diaphragm to float upward to dispense fluid through the Body
to the Dispense Tip.
Wetted parts on the Model 200 are made of Delrin®, Teflon®, stainless steel, and
polyethylene.
Figure 1. Model 200 Internal Component Diagram