Ú Installation instructions

Important notes

Read these instructions carefully and keep them in a safe place.
Safety during use can only be ensured if the appliance is fitted
correctly according to these installation instructions. The installer
is responsible for ensuring that the appliance operates perfectly at
the point of installation.
The appliance must be connected to the mains only by a licensed
and trained technician.
Before carrying out any type of work, turn off the electricity.
For installation, currently applicable building regulations and the
regulations of the local electricity supplier must be observed.
This appliance corresponds to appliance class 3 (for installation in
a kitchen unit). It must be fitted according to the installation
drawing. Observe the minimum distance to side walls or furniture
parts and to the rear wall.
This appliance is not intended for operation with an external timer
or an external remote control.
Preparing the furniture
The surrounding kitchen unit must be heat-resistant to at least
90 °C. The stability of the unit must be maintained after producing
the cut-out.
Produce the cut-out for one or several Vario appliances. Proceed
as shown in the installation sketch. The angle between the cut
surface and the worktop must be 90°.
After producing the cut-out, remove the shavings. Seal the cut
surfaces to make them heat-resistant.
Observe a minimum clearance between the appliance housing
and parts of the unit of 10 mm.
Protection against accidental contact from below must be
guaranteed after installation. If the underside of the appliance can
be touched after installation, an intermediate shelf must be fitted
that can only be removed using a tool. Observe a minimum
clearance between the appliance and the shelf of 10 mm.
When fitting several Vario appliances: allow for the additional
space required for the connecting strip VV 200. Appliances can
also be fitted in individual recesses, if a minimum clearance of
40 mm between the appliances is observed.

Electrical connection

Check the electrical installation system before connecting the
appliance. Make sure that the household installation has sufficient
fuse or circuit breaker protection. Check that the appliance has the
same voltage and frequency as the electrical installation system
(see rating plate).
The appliance corresponds to protection class I and may only be
operated with a protective earth connection.
The installation system must incorporate an all-pole isolating
switch with a contact gap of at least 3 mm. This must remain
accessible after installation.
Only a qualified electrician who takes the appropriate regulations
into account may connect or replace the mains connection cable.
Appliance without mains connection cable: Only connect as shown
on the connection diagram. If necessary, fit the copper bridge
supplied. Mains connection cable: Type H05 VV-F or higher rated.
Observe the minimum cross section. The yellow/green wire for the
PE connection must be 10 mm longer than the other wires on the
appliance side.
Do not kink or trap the mains connection cable.
Fitting the appliance
Mark the centre of the recess exactly. Fit the short mounting rail
1.
to the front of the recess and the long mounting rail to the rear of
the recess. Make sure the lugs of the mounting rails lie on the
worktop. The centre marking on the mounting rails must be
precisely flush with the centre marking of the recess.
Note: when fitting the appliance in a stone worktop glue on the
mounting rails with a temperature-resistant two-component
adhesive (metal on stone).
Lower the appliance into the cut-out. The snap-in pins on the
2.
appliance must lie exactly on the catch springs. Firmly press the
appliance into the cut-out. The pins on the appliance must snap
into the catch springs.
Special instructions for installation outdoors
Operate the appliance on a residual current device (RCD) with a
maximum tripping current of 30 mA.
The appliance corresponds to protection class I and may only be
operated with a protective earth connection.
Check the mains cable regularly for signs of damage. Do not use
the appliance if the mains cable is damaged.
The mains cable must be rated at least to H07RN-F-5G1,5.
The appliance must be fitted into a worktop. Prevent moisture from
penetrating.
The appliance must be protected from weather after use and
cooling down (e.g. with a cover).

Removing the appliance

Disconnect the appliance from the power supply. Push out the
appliance from below.
Caution!
Risk of damage! Do not lever out the appliance from above.