ADEMCO 4110XM Manuale di istruzioni per l'installazione - Pagina 6
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Sistema di sicurezza ADEMCO 4110XM. ADEMCO 4110XM 20.
–––––––––––––––––––––––––– COMPATIBLE DEVICES –––––––––––––––––––––––––––
Remote Keypads (up to 4)
Model
4127, 6127
4137AD, 6137, 6128
5330 (Select for Vista)
Addressable keypads must be used in
the non-addressable mode (Device
Address 31), which is pre-set at the
IMPORTANT
factory. Do not set these keypads to
any other addresses.
Smoke Detectors (4-wire only)
Model
Type
1412
Ionization Products of Combustion
Detector
2412
Photoelectric Smoke Detector
2412TH
Photoelectric Smoke Detector)w/135º F
(57º C) Heat Detector)
Fire Supervisory Module
A77-71601 EOL Relay Module (supervises power
for 4-wire fire zone).
––––––––––––––––– ZONE RESPONSE TYPE CHARACTERISTICS –––––––––––––––––
Zone Response Type
0 – Zone Disabled
1 – Entry/Exit Burglary
3 – Perimeter Burglary
4 – Interior, Follower
5 – Trouble by Day/Alarm by
Night
6 – 24-Hr. Silent Alarm
7 – 24 Hr. Audible Alarm
8 – 24-Hr. Auxiliary Alarm
9 – Fire
10 – Interior w/Delay
Type
Fixed English
Fixed English Addressable
Alpha
Characteristics
• Provides exit delay time when panel is armed in any arming mode.
• Provides entry delay when panel is armed in Away and Stay modes
only.
• Provides an instant alarm when panel is armed in any arming mode.
• Provides exit delay time when panel is armed in any mode.
• Will only provide entry delay if an Entry/Exit zone is faulted first upon
entry. Otherwise, alarm will be instant.
• Bypassed automatically when panel is armed in the Stay or Instant
mode.
• Provides a trouble response if panel is not armed when zone is faulted.
• Provides an instant alarm if panel is armed in any mode.
• Provides a silent alarm to Central Station whether panel is armed or
disarmed.
• Provides an audible alarm at the bell output and keypad whether panel
is armed or disarmed.
• Provides an audible alarm at the keypad only. No bell output is
provided.
• Provides a fire alarm when zone is shorted. Causes bell output to pulse.
• Provides a trouble response when zone is open.
• Provides entry and exit delay times.
• Bypassed automatically when panel is armed in the Stay or Instant
mode.
5700 Series Transmitters
Model
Description
5701
Panic Transmitter
5706
Photoelectric Smoke
5707
Detectors
5711
Slimline Door/
Window Transmitter
5715WH Universal Transmitter
5716
Door/Window
5716WM Transmitter
5742
Audio Discriminator
5743
Dual Technology
Glassbreak Detector
5775
PIR Detector
5727
Wireless Keypad
5827BD
Wireless Bi-directional
Keypad
5799
Magnets
U L
The 5711, 5715, and 5716 do not supervise
their loop wiring. Therefore, their loop
wiring may not exceed three feet.
Optional Keyswitch
4116 Keyswitch
-6-
Zone Num.
62 or 63
48-55
1-63
1-63
1-63
1-63
1-63
32-47
House ID
House ID