–––––––––––––––––––––––––– COMPATIBLE DEVICES –––––––––––––––––––––––––––
Remote Keypads (up to 4)
Model
4127, 6127
4137AD, 6137, 6128
5330 (Select for Vista)
Addressable keypads must be used in
the non-addressable mode (Device
Address 31), which is pre-set at the
IMPORTANT
factory. Do not set these keypads to
any other addresses.
Smoke Detectors (4-wire only)
Model
Type
1412
Ionization Products of Combustion
Detector
2412
Photoelectric Smoke Detector
2412TH
Photoelectric Smoke Detector)w/135º F
(57º C) Heat Detector)
Fire Supervisory Module
A77-71601 EOL Relay Module (supervises power
for 4-wire fire zone).
––––––––––––––––– ZONE RESPONSE TYPE CHARACTERISTICS –––––––––––––––––
Zone Response Type
0 – Zone Disabled
1 – Entry/Exit Burglary
3 – Perimeter Burglary
4 – Interior, Follower
5 – Trouble by Day/Alarm by
Night
6 – 24-Hr. Silent Alarm
7 – 24 Hr. Audible Alarm
8 – 24-Hr. Auxiliary Alarm
9 – Fire
10 – Interior w/Delay
Type
Fixed English
Fixed English Addressable
Alpha
Characteristics
• Provides exit delay time when panel is armed in any arming mode.
• Provides entry delay when panel is armed in Away and Stay modes
only.
• Provides an instant alarm when panel is armed in any arming mode.
• Provides exit delay time when panel is armed in any mode.
• Will only provide entry delay if an Entry/Exit zone is faulted first upon
entry. Otherwise, alarm will be instant.
• Bypassed automatically when panel is armed in the Stay or Instant
mode.
• Provides a trouble response if panel is not armed when zone is faulted.
• Provides an instant alarm if panel is armed in any mode.
• Provides a silent alarm to Central Station whether panel is armed or
disarmed.
• Provides an audible alarm at the bell output and keypad whether panel
is armed or disarmed.
• Provides an audible alarm at the keypad only. No bell output is
provided.
• Provides a fire alarm when zone is shorted. Causes bell output to pulse.
• Provides a trouble response when zone is open.
• Provides entry and exit delay times.
• Bypassed automatically when panel is armed in the Stay or Instant
mode.
5700 Series Transmitters
Model
Description
5701
Panic Transmitter
5706
Photoelectric Smoke
5707
Detectors
5711
Slimline Door/
Window Transmitter
5715WH Universal Transmitter
5716
Door/Window
5716WM Transmitter
5742
Audio Discriminator
5743
Dual Technology
Glassbreak Detector
5775
PIR Detector
5727
Wireless Keypad
5827BD
Wireless Bi-directional
Keypad
5799
Magnets
U L
The 5711, 5715, and 5716 do not supervise
their loop wiring. Therefore, their loop
wiring may not exceed three feet.
Optional Keyswitch
4116 Keyswitch
-6-
Zone Num.
62 or 63
48-55
1-63
1-63
1-63
1-63
1-63
32-47
House ID
House ID