1.0
DY 4000
Message Display / Gycle Counter
Message Display Readings
1. Follow table to translate display readings on initial power up. See table 1.0-1
T ab l e 1 . 0 -1: D isp l ay C h ar t
2. DY4000 has a two line display. See figure 1.0-2
FIRST LINE DISPLAYS
DIFFERENT MESSAGES OF
OPERATION
isEGoND L|NE DTSPLAYS
J CYCIe COUNTER / TIMER
, S E T T I N G S
Figure 1.0-2: DY4000 display
Note: Most error codes can be reset usino the JOG UP/RESET button
Means its ready to go and the
number below is the cycle counter
Operate door
Means the Variable Frequency Drive
went into error
Check drive display for error code
(refer:N/A)
Means the reversing edge is staying
or was activated
Check pneumatic switch for proper
operation / Normal if activated
Means the open run timer has
expired
Reset unit (via up jog reset) / check
open run timer setting (refer: Pg7)
Means the closed run timer has
expired
Reset unit (via up jog reset) / check
closed run timer setting (refer: Pg7)
Means to set limits do to loss of
limits or new install
Set Limits (refer: Pgs 3-6)
Means that the DY4000 lost encoder
feedback
Gheck if encoder connected and
wired correctly (refer: N/A)
READY
562
2
DYNACO USA. INC.
1te ^4ead"en
cnDaa S"l"tl &Deuy