DYNACO DY 4000 Manuale elettrico - Pagina 8
Sfoglia online o scarica il pdf Manuale elettrico per Pannello di controllo DYNACO DY 4000. DYNACO DY 4000 12.
Run Timers
3.0
Setting the Open and Close Run Timers
DYNACO USA, INC,
The Open Run Timer and Close Run Timer act as a failsafe, to prevent the
door from running continuously, when open or close limit switch fail to stop
door. These timers should be set for a period that exceeds the duration of a full
open or close cycle.
1. Press and release Open Run Timer button on the Dynalogix II controller.
The display will change to: Opening_Time=##. See figure 3.0-1.
RUN
TIMERS
OPEN
JOG
UP/RESET
JOG
MC/PB
DOWN
CLOSE
TIMERS
MENU
Figure 3.0-1: Run Timers
2. Use the Up and Down arrow buttons to change the countdown time to the
desired duration. The Dynalogix II will automatically save any changes that
are made. See Figure 3.0-2.
RUN
TIMERS
OPEN
JOG
UP/RESET
JOG
MC/PB
DOWN
CLOSE
TIMERS
MENU
Figure 3.0-2: Raise/Lower Run Timers
3. Repeat steps 1 and 2 to set the Close Run Timer.
CLOSE
PROGRAM
AC/LOOP
ENTER
CLOSE
PROGRAM
AC/LOOP
ENTER
The Leader in Door Safety & Design
7
Open/Close
Run Timers
MESSAGE DISPLAY / COUNTER
Opening
Time=##
Increase
Setting
Decrease
Setting