Dynamic Power TriFuel Manuale d'uso - Pagina 11

Sfoglia online o scarica il pdf Manuale d'uso per Inverter Dynamic Power TriFuel. Dynamic Power TriFuel 17. Triple fuel generator. trifuel-red

4. Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine
several revolutions to distribute the oil, and then reinstall the spark plug.
5. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke
and both the intake and exhaust valves are closed. Storing the engine in this position will help to protect is from
internal corrosion.

SPECIFICATIONS

ENGINE
CYLINDERS
DISPLACEMENT
IGNITION
COOLING
FUEL TANK
LUBE OIL VOL.
GENERATOR
PHASE
VOLTAGE
DB(A)
FREQ./RPM
CONT. OUTPUT
MAX OUTPUT
CONT. OPERATING HOURS
WEIGHT
(L x W x H)

TROUBLESHOOTING

PROBLEM
Engine will not start
No AC output
Voltage low
Generator overheating
15 hp
Single Cylinder, OHV 4 Cycle
420 cc
Electric / TCI
Air Cooled
6 Gal, Tri-fuel powered
1.1 L /37 fl. oz
Electric Brushless
Single
120V / 240V, 12V DC
7m 68
60Hz/3600Rpms
8 KW
9 KW
6
310 lbs dry
POSSIBLE CAUSE
Out gas or LPG
Low oil level
Fouled spark plug
Fuel valve turn off
Plugged fuel filter
Tripped AC circuit breaker
Engine speed low
AC overloaded
Defective stator, rotor, or capacitor
Bad ventilation
Overloaded
10
SOLUTION
Refill tank
Add more 10W-30 oil
Replace it if necessary
Turn on fuel valve
Change fuel filter
Remove load, check for defects
Increase speed
Remove some load
Replace with good one
Improve ventilation
Remove some load