1.1 Anchor Design and Application

The Anchor on the Go™ Portable Roof Anchor for Metal Roofs has been
designed and tested to 15kN and is therefore rated as a single person fall
arrest anchor under AS/NZS1891.4. It is only suitable for use on roofs
constructed with metal roof sheeting with a minimum BMT of 0.42mm
in the following profiles – Custom Orb, Trimdek, Spandek and Klip-Lok
406 & Klip-Lok 700 provided ridge-capping is secured in place with roof
screws per manufacturer's instructions.
IMPORTANT: The Anchor on the Go™ Portable Roof Anchor is NOT
suitable for tiled, shingled, aluminium sheet, asbestos or decramastic
roofs.
IMPORTANT: This anchor is designed to be attached to the opposite
side of the roof from where you intend to work. Do NOT connect to or use
the anchor on the same side of the roof where the anchor is connected.
If a second person is required to work on the roof, a second anchor
device must be used. Connecting two lines to a single anchorage device is
NOT permitted. Where two connecting devices are attached to the same
anchorage point (e.g. two snap hooks), the snap hooks may rub against
each other, causing them to be entangled or even become disengaged
from the anchorage device.
Additionally, testing has concluded that whilst this device can sustain a
load of 22kN, the roof sheeting profiles most commonly used in Australia
and New Zealand will not sustain a static load greater than 15kN.
IMPORTANT: Do NOT work outside an arc of 30 degrees either side of
the centre line of the anchorage location to reduce the danger of swing
fall hazards - refer to Figure One over the page.
The user
of this
Anchor on the Go™ Portable Roof Anchor shall be
trained and ensure that care is taken to adjust the safety line length so
that he/she will not be able to fall off the ends of the roof.
IMPORTANT: Anchor on the Go™ Portable Roof Anchor is NOT suitable
for use as an anchorage device for a Temporary Horizontal Life Line.