Setup:
Tilt fulcrum back until the lines on top of fulcrum and arm
base line up.
1 Attach the counter weight tube to the front of the C-pan.
2. Insert the lock pin
Attach camera to the camera plate. The camera screw
has a 1/4" thread on one side and 3/8" on the other.
Check the levelling bubble to insure that the C-pan is set
level in all directions.
Place counter weights on tube. Place the weights as needed
(depending on camera weight) to reach a safe operating
balance. Weights can be set at different positions on the
tube to increase or decrease counter balance. It is important
to test the C-Pan arm at its maximum reach with the camera
mounted to set the right weight requirement.
Use the camera plate tilt to position the camera lens in the
middle of the two arms