Autonics TN Series Manuale del prodotto - Pagina 3

Sfoglia online o scarica il pdf Manuale del prodotto per Controllore Autonics TN Series. Autonics TN Series 5. Two-degree-of-freedom pid temperature controllers
Anche per Autonics TN Series: Manuale del prodotto (6 pagine), Manuale di istruzioni (2 pagine)

Autonics TN Series Manuale del prodotto
Input Type and Using Range
The setting range of some parameters is limited when using the decimal point display.
Decimal
Input type
Display
point
1
K (CA)
0.1
1
J (IC)
0.1
1
E (CR)
0.1
1
T (CC)
0.1
B (PR)
1
R (PR)
1
Thermo
S (PR)
1
-couple
N (NN)
1
C (TT)
1
01)
G (TT)
1
02)
1
L (IC)
0.1
1
L (RUS)
0.1
1
U (CC)
0.1
Platinel II
1
Cu50 Ω
0.1
Cu100 Ω
0.1
1
JPt100 Ω
0.1
RTD
DPt50 Ω
0.1
1
DPt100 Ω
0.1
Nickel120 Ω 1
0 to 10 V
-
0 to 5 V
-
1 to 5 V
-
Analog
0 to 100 mV
-
0 to 20 mA
-
4 to 20 mA
-
• Permissible line resistance per line: ≤ 5 Ω
01) C (TT): Same as existing W5 (TT) type sensor
02) G (TT): Same as existing W (TT) type sensor
■ Display accuracy
Input type Using temperature
Display accuracy
(PV ±0.2% or ±1 ℃ higher one) ±1-digit
• Thermocouple K, J, T, N, E below -100 ℃ and L, U, PLII,
RTD Cu50 Ω, DPt50 Ω: (PV ±0.3% or ±2 ℃ higher one)
At room temperature
±1-digit
(23℃ ±5 ℃)
• Thermocouple C, G and R, S below 200 ℃:
(PV ±0.3% or ±3 ℃ higher one) ±1-digit
Thermo
• Thermocouple B below 400 ℃: There is no accuracy
-couple
standards
RTD
(PV ±0.5% or ±2 ℃ higher one) ±1-digit
• RTD Cu50 Ω, DPt50 Ω: (PV ±0.5% or ±3 ℃ higher one)
Out of room
±1-digit
temperature range
• Thermocouple R, S, B, C, G:
(PV ±0.5% or ±5 ℃ higher one) ±1-digit
• Other sensors: ≤ ±5 ℃ (≤-100 ℃)
At room temperature
±0.2% F.S. ±1-digit
(23℃ ±5 ℃)
Analog
Out of room
±0.5% F.S. ±1-digit
temperature range
Using range (℃)
Using range (℉)
-200 to 1,350
-328 to 2,463
KCaH
-199.9 to 999.9
-199.9 to 999.9
KCaL
-200 to 800
-328 to 1,472
JIcH
-199.9 to 800.0
-199.9 to 999.9
JIcL
-200 to 800
-328 to 1,472
ECrH
-199.9 to 800.0
-199.9 to 999.9
ECrL
-200 to 400
-328 to 752
TCcH
-199.9 to 400.0
-199.9 to 752.0
TCcL
0 to 1,800
B'PR
0 to 1,750
R'PR
0 to 1,750
S'PR
-200 to 1,300
-328 to 2,372
N'NN
0 to 2,300
C'TT
0 to 2,300
G'TT
-200 to 900
-328 to 1,652
LIcH
-199.9 to 900.0
-199.9 to 999.9
LIcL
-200 to 800
-328 to 1,472
LrH
-199.9 to 800.0
-199.9 to 999.9
LrL
-200 to 400
-328 to 752
UCcH
-199.9 to 400.0
-199.9 to 752.0
UCcL
0 to 1,390
PLII
-199.9 to 200.0
-199.9 to 392.0
CU'5
-199.9 to 200.0
-199.9 to 392.0
CU10
-200 to 650
-328 to 1,202
JPtH
-199.9 to 650.0
-199.9 to 999.9
JPtL
-199.9 to 600.0
-199.9 to 999.9
DPT5
-200 to 650
-328 to 1,202
DPtH
-199.9 to 650.0
-199.9 to 999.9
DPtL
-80 to 200
-112 to 392
NI12
0 to 10 V
AV1
0 to 5 V
AV2
1 to 5 V
AV3
0 to 100 mV
AMV1
0 to 20 mA
AMA1
4 to 20 mA
AMA2

Unit Descriptions

• Below is based on TNL Series.
• The shape and function of each part may be different depending on the series, and
it is possible to check the additional information in the user manual.
4
32 to 3,272
5
32 to 3,182
32 to 3,182
6
32 to 4,172
32 to 4,172
8
5. Operation status indicator
Display Name
32 to 2,534
LOCK
Lock
PROG
Program
WAIT
Wait
Heater break
HBA1/2
alarm
6. Output status indicator
Display Name
Control
OUT1/2
output
AT
Auto tuning
Manual
MAN
control
Control
STOP
output stop
Program
HOLD
control hold
Alarm
AL1 to 6
output
Errors
Display Input
Temperature
sensor
OPEN
Analog
Temperature
sensor
HHHH
Analog
Temperature
sensor
LLLL
Analog
ERR -
1. PV display part (White)
RUN mode: Displays PV (Present value) and unit.
Setting mode: Displays parameter name
2. SV display part (Green)
RUN mode: Displays SV (Setting value) and unit.
1
Setting mode: Displays parameter setting value.
3. Operating value display part (Yellow)
2
RUN mode: Displays selected value among MV
(Manipulated output value), CT, TIME with unit.
3
4. Temperature control indicator
• Fixed control: Relative PV value status display
based on SV
PV > SV (↗), PV = SV (→), PV < SV (↘)
7
• Program control: Displays temperature control
status of up (↗), hold (→), down (↘).
Description
Turns ON during key lock status.
Turns ON during program
control.
Turns ON during waiting status.
Turns ON when the heater
break alarm output is ON.
Description
Turns ON when the control output
is ON
Flashes during auto tuning every 1
sec
Turns ON during manual control
mode
Turns ON during control output
stop mode
Turns ON when program control
is hold status
Turns ON when the alarm output
is ON
Description
Output
Flashes at 0.5 sec interval when
'Sensor error,
input sensor is disconnected or
MV' parameter
sensor is not connected.
setting value
'Sensor error,
Flashes at 0.5 sec interval when
MV' parameter
input is over F.S. ±10%.
setting value
Flashes at 0.5 sec interval if the
Heating: 0%,
input value is above the input
Cooling: 100%
range.
Flashes at 0.5 sec interval if the
input value is over 5 to 10% of high
Normal output
limit or low limit value.
Flashes at 0.5 sec. interval if the
Heating: 100%,
input value is below the input
Cooling: 0%
range.
Flashes at 0.5 sec interval if the
input value is over 5 to 10% of low
Normal output
limit or high limit value.
Flashes at 0.5 sec interval if there
is error for setting and it returns to
-
the error-before screen.
7. Input key
Display
Name
[U]
User key
[M]
Mode key
Setting value
[◀], [▼], [▲]
control key
8. PC loader port
For connecting
communication converter
(SCM-USP).
Troubleshooting
Check input
sensor status.
Check analog
input status.
When input is
within the rated
input range,
this display
disappears.
Check setting
method.