Autonics PSQ-C01 Series Scheda tecnica - Pagina 3
Sfoglia online o scarica il pdf Scheda tecnica per Strumenti di misura Autonics PSQ-C01 Series. Autonics PSQ-C01 Series 14. Dual lcd display digital pressure sensor
Compact, Dual LCD Display Digital Pressure Sensor
Unit Description
1
2
3
4
5
Dimensions
Pneumatic type
30
24.8
Fluid type
30
Accessory
Connector cable (PSO-C01, Pneumatic/Fluid type)
※ Ø4mm, 5-wire, 2m
( AWG24, core diameter: 0.08mm,
number of cores: 40,
insulator diameter: Ø1mm)
1. Present value (PV) display part (green, red, orange by setting/status)
RUN mode: Displays PV.
Setting mode: Displays parameter.
2. Setting value (SV) display part (green)
RUN mode: Displays setting value, unit, etc.
Setting mode: Displays SV.
3. Output indicator (OUT1, OUT2) (orange): Turns ON while the control output turns ON.
4.
key
M
RUN mode: Press the
key for over 2 sec to enter parameter 1 group.
M
Press the
key for over 4 sec to enter parameter 2 group.
M
Setting mode: Press the
key to select the setting items.
M
Press the
key for over 2 sec to return RUN mode.
M
5.
key
,
RUN mode: Press the
,
Press the
+
M
Press the
+
Press the
+
M
Preset value setting
mode: Press the
Setting mode: Changes the parameter.
32.7
7.9
Rc(PT)1/8"
30
12.3
A
Inside
M5 Tap
17
Ø4, 3m
key to set preset value of output operation mode.
keys to set key lock/unlock.
keys to adjust zero point.
keys to set peak hold.
,
key to increase/decrease setting value.
2-M3
20
2-M3
20
(unit: mm)
32.7
A
24.8
7.9
Inside M5 Tab
※ A
R1/8 model
8mm
NPT1/8 model
※ A
8mm
R1/8 model (standard)
0mm
Rc1/8 model
R1/4 model
11.5mm
NPT1/4 model
9/16-18UNF model
15.4mm
(metal gasket sealing method)
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(A)
Photoelectric
Sensors
(B)
Fiber Optic
Sensors
(C)
LiDAR
(D)
Door/Area
Sensors
(E)
Vision
Sensors
(F)
Proximity
Sensors
(G)
Pressure
Sensors
(H)
Rotary
Encoders
(I)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets
G-11