need to use the manual shut-off valve to turn the water off in case of an emergency
(see Emergency Procedures on page 19 to turn water on) . When power is restored,
the WaterCop® will remain in its last known position indicated by the red or green
lights on the face of the unit .
WaterCop® Specifications
Actuator
Max . working pressure
Ambient temperature
Enclosure
Voltage
Current
Accessories
Sensor Signal Repeater
Sensors
Valve
Valve
Valve seals
Flow Data
Valve Size Cv = Gpm flow at 1 psi pressure drop
½" NPT
19
¾" NPT
34
For cold water applications

FCC Information

This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules . These limits are designed to
8
The valve will remain closed until the unit is
manually reset on the WaterCop® panel .
After the plumbing problem is fixed, reset the
WaterCop® by pressing OPEN (green circle) on
the face of the WaterCop® . Valve will open and
green indicator will be lit . (See illustration . )
Note: If major repairs are needed to correct
the plumbing system, it is recommended that
the manual shut-off valve upstream of the
WaterCop® also be closed during the repairs .
Close the main water shut-off valve and unplug
the WaterCop® before making repairs on the
plumbing system .
Note: In case of a power failure, the WaterCop®
cannot operate . If the power is out, you will
125 psig
35° to 105° F
Polycarbonate
12 VDC plus 120 VAC adapter
0 . 8 5 Amps (Full Load)
120 VAC 47mA
3 VDC (2AA Batteries) 10mA
Full-Port, Lead-Free Brass, NPT
RTFE (Reinforced Teflon®)
1" NPT
52
1¼" NPT
77