Highland heat Kompakt 16 Manuale d'uso - Pagina 11

Sfoglia online o scarica il pdf Manuale d'uso per Caldaia Highland heat Kompakt 16. Highland heat Kompakt 16 20. Solid fuel boiler

Kompakt
4. Boiler installation

4.6 Changing the door direction

1
1. Screw DIN 912 M10x16
2. Screw DIN 912 M10x12
3. Eccentric M10
The direction of the upper and middle doors is changed by
turning the door together with the hinge (hinges) away from the
boiler body and screwing it on the opposite side of the boiler.
The door handle is unscrewed, turned over and screwed back.
The direction of the lower door is changed by turning the door
away from the hinge. The hinge is unscrewed from the boiler
body and screwed on the opposite side of the boiler. The door
is screwed to the hinge, and the door handle is unscrewed from
the door and screwed to the opposite side of the door. The
draft regulator is fixed at the top of the boiler depending on the
direction of door opening. The chain mounting plate is mounted
on the hinge side.
11
2
3
4
5
6
4. Door handle
5. Spring washer
6. Screw DIN 912 M8x14