HighSecLabs FVFE11PH-M Manuale di configurazione rapida - Pagina 8

Sfoglia online o scarica il pdf Manuale di configurazione rapida per Estensore HighSecLabs FVFE11PH-M. HighSecLabs FVFE11PH-M 10. Secure kvm extenders
Anche per HighSecLabs FVFE11PH-M: Manuale di configurazione rapida (9 pagine)

SECTIONS
Table of Contents

oPERaTIoN

Running an EDID Capture
before using the Extender, run a one-time EDID capture on both sides
– Transmitter and Receiver. This prevents the continuous transfer of
potentially malicious data - from the display to the PC – that could
infect the PC, cause data leakage, and so on.
Preparation:
• Connect the PC and all peripherals to both the units, according to
the Installation Instructions.
• Make sure the PC, display, and the units are oN.
To run an EDID capture:
1. on the Receiver, short-click the EDID lock button. Wait 5 seconds
and then restart the unit, by unplugging the network cable and
power supply. at first, the EDID lED flickers for a few seconds and
then, once captured lights green continuously.
2. Make same on the Transmitter, short-click the EDID lock button,
wait 5 seconds and then restart the unit. The EDID lED will now light
green continuously.
Note: If the EDID lED is off, check the connections and that the PC
or the Display are powered oN. Then, repeat the procedure.
3. Restart both units.
Note: an EDID capture needs to be performed for new installations
and when changing a display.
HSL Secure Extended Isolators Quick Setup Guide
1
2
EDID LED
3
EDID Lock Button
EDID LED
EDID Lock Button
Receiver
Transmitter
7