Recommendation: For best practice no more than 35" (88.9 cm) of 900 µm fiber be exposed for the MDU
drop cable installation process. This length will optimize the routing capability within the IDC and prevent
excessive lengths of 900 µm fiber from collecting within the cabinet.
5. Insert the 4.8mm jacket into the drop retention bracket. (Figure 24)
Figure 22
6. Slide the 4.8 mm drop cable to the backmost position within the drop retention bracket.
7. Ensure that the exposed 900 µm fiber is long enough
to reach the desired IDEAA Splitter Module port.
8. Repeat steps 4 – 7 for all desired MDU drop cables.
9. Once all MDU drop cables have been installed, replace
the drop access plate.
10. Using a standard 216 style tool, or similar, replace the
two nuts that secure the MDU drop access plate to the
cabinet body and cover with caps. (Figure 25)
11. Install FASTConnect
®
Reference the installation instructions provided with the
FASTConnect
Mechanical Connector. The document
®
will include the following:
• Fiber Preparation
• Fiber Termination
• Connector Assembly
12. Using local engineering practices, determine which
port on the IDEAA Splitter Module will be used for
the MDU drop connection.
13. Use local accepted practices to clean the distribution
fiber connector end face.
14. Connect the distribution fiber to the appropriate port on
the IDEAA Splitter Module. Use the foam fiber relief to
route the distribution fiber to the fiber routing section
of the IDC, employing a similar technique to that used
with the input jumper cable. (Figure 26)
Mechanical Connector.